Installation guide
Table Of Contents
- Command Line Interface
- Reference Guide
- Introduction
 - General Control Commands
 - container Commands
- container add_level
 - container create mirror
 - container create mmirror
 - container create mstripe
 - container create mvolume
 - container create raid5
 - container create stripe
 - container create volume
 - container delete
 - container extend file_system
 - container extend mvolume
 - container extend volume
 - container list
 - container lock
 - container move
 - container promote
 - container readonly
 - container readwrite
 - container reconfigure
 - container release_cache
 - container remove drive_letter
 - container remove failover
 - container remove file_system
 - container remove global_failover
 - container restore RAID5
 - container scrub
 - container set cache
 - container set failover
 - container set global_failover
 - container set io_delay
 - container set label
 - container show cache
 - container show failover
 - container split
 - container unlock
 - container unmirror
 
 - controller Commands
- controller details
 - controller firmware compare
 - controller firmware save
 - controller firmware update
 - controller list
 - controller pause_io
 - controller rescan
 - controller reset_scsi_channel
 - controller resume_io
 - controller set automatic_failover
 - controller set array_verify
 - controller show automatic_failover
 - controller show channels
 - controller show array_verify
 
 - disk Commands
 - diagnostic Commands
- diagnostic clear boot_parameters
 - diagnostic dump structures
 - diagnostic dump text
 - diagnostic load_arrays
 - diagnostic moderation set count
 - diagnostic moderation set timer
 - diagnostic moderation show count
 - diagnostic moderation show timer
 - diagnostic set boot_parameter
 - diagnostic show boot_parameter
 - diagnostic show history
 
 - logfile Commands
 - task Commands
 - enclosure Commands
- enclosure activate slot
 - enclosure identify slot
 - enclosure list
 - enclosure prepare slot
 - enclosure set alarm
 - enclosure set door
 - enclosure set fan
 - enclosure set interval
 - enclosure set power
 - enclosure set scsiid
 - enclosure set temperature
 - enclosure show fan
 - enclosure show power
 - enclosure show slot
 - enclosure show status
 - enclosure show temperature
 
 - Automated Scripts
 
 
 - Reference Guide
 

3-100
container Commands
The following example creates a mirror set asynchronously and 
sets an I/O delay of 20 milliseconds for array 0. You need to 
perform the create mirror task asynchronously. Otherwise, you 
cannot change the I/O delay:
container create mirror /io_delay=20 0 (0,2,0)
Executing container create mirror /io_delay=20 0 (CHANNEL=0,ID=2,LUN=0)
The following example shows how to change the I/O delay to 40 
milliseconds on the currently running create mirror task:
AAC0>container set io_delay 0 40
Executing: container set io_delay 0 40
Use the container list command after using the container 
set io_delay
 command to display information about the array, 
as in the following example:
AAC0>container list
Executing: container list
Num Total Oth Stripe  Scsi Partition 
Dr Label Type Size Ctr Size Usage  C:ID:L Offset:Size 
-- ----- ------ ------ --- ------ ------- ------ ------------- 
F: 0 Volume 10.0MB NTFS 0:02:0 64.0KB: 10.0MB
As the example shows, there is no difference between the array list 
display prior to and after the set I/O delay operation.
Related Commands
container commands: 
■ container create mirror (page 3-5)
■ container create mmirror (page 3-8)
■ container list (page 3-50)
■ container scrub (page 3-88)