Installation guide
Table Of Contents
- Command Line Interface
- Reference Guide
- Introduction
 - General Control Commands
 - container Commands
- container add_level
 - container create mirror
 - container create mmirror
 - container create mstripe
 - container create mvolume
 - container create raid5
 - container create stripe
 - container create volume
 - container delete
 - container extend file_system
 - container extend mvolume
 - container extend volume
 - container list
 - container lock
 - container move
 - container promote
 - container readonly
 - container readwrite
 - container reconfigure
 - container release_cache
 - container remove drive_letter
 - container remove failover
 - container remove file_system
 - container remove global_failover
 - container restore RAID5
 - container scrub
 - container set cache
 - container set failover
 - container set global_failover
 - container set io_delay
 - container set label
 - container show cache
 - container show failover
 - container split
 - container unlock
 - container unmirror
 
 - controller Commands
- controller details
 - controller firmware compare
 - controller firmware save
 - controller firmware update
 - controller list
 - controller pause_io
 - controller rescan
 - controller reset_scsi_channel
 - controller resume_io
 - controller set automatic_failover
 - controller set array_verify
 - controller show automatic_failover
 - controller show channels
 - controller show array_verify
 
 - disk Commands
 - diagnostic Commands
- diagnostic clear boot_parameters
 - diagnostic dump structures
 - diagnostic dump text
 - diagnostic load_arrays
 - diagnostic moderation set count
 - diagnostic moderation set timer
 - diagnostic moderation show count
 - diagnostic moderation show timer
 - diagnostic set boot_parameter
 - diagnostic show boot_parameter
 - diagnostic show history
 
 - logfile Commands
 - task Commands
 - enclosure Commands
- enclosure activate slot
 - enclosure identify slot
 - enclosure list
 - enclosure prepare slot
 - enclosure set alarm
 - enclosure set door
 - enclosure set fan
 - enclosure set interval
 - enclosure set power
 - enclosure set scsiid
 - enclosure set temperature
 - enclosure show fan
 - enclosure show power
 - enclosure show slot
 - enclosure show status
 - enclosure show temperature
 
 - Automated Scripts
 
 
 - Reference Guide
 

5-8
disk Commands
The Rev Column
The Rev column displays the revision number of the SCSI device.
The Block Column
The Block column displays the number of blocks available on the 
SCSI device.
The Bytes/Block Column
The Bytes/Block column displays the number of bytes for each 
block on the SCSI device.
The Usage Column
The Usage column displays the usage of the SCSI device. The disk 
list command can display one of the values listed in Table 5-2.
Table 5-2 SCSI Disk Device Usage Values
The Shared Column
The Shared column displays the value YES if the device resides on 
a shared channel and the value NO if the device does not reside on 
a shared channel. In the example, the devices do not reside on a 
shared channel.
Value Meaning
Detached The system detected that the diskset in the detached 
state. When a diskset is detached, it is not available 
for use.
DOS The SCSI device was prepared for use (initialized) 
with MS-DOS partitions.
Initialized The SCSI device was prepared for use (initialized) 
with arrays.
Not Initialized The SCSI device was not prepared for use 
(initialized) with arrays.
Offline The SCSI device was present at boot time. 
However, the device is either removed from the 
controller or it failed.
Unowned The controller does not own the SCSI device.