Installation guide
Table Of Contents
- Command Line Interface
- Reference Guide
- Introduction
- General Control Commands
- container Commands
- container add_level
- container create mirror
- container create mmirror
- container create mstripe
- container create mvolume
- container create raid5
- container create stripe
- container create volume
- container delete
- container extend file_system
- container extend mvolume
- container extend volume
- container list
- container lock
- container move
- container promote
- container readonly
- container readwrite
- container reconfigure
- container release_cache
- container remove drive_letter
- container remove failover
- container remove file_system
- container remove global_failover
- container restore RAID5
- container scrub
- container set cache
- container set failover
- container set global_failover
- container set io_delay
- container set label
- container show cache
- container show failover
- container split
- container unlock
- container unmirror
- controller Commands
- controller details
- controller firmware compare
- controller firmware save
- controller firmware update
- controller list
- controller pause_io
- controller rescan
- controller reset_scsi_channel
- controller resume_io
- controller set automatic_failover
- controller set array_verify
- controller show automatic_failover
- controller show channels
- controller show array_verify
- disk Commands
- diagnostic Commands
- diagnostic clear boot_parameters
- diagnostic dump structures
- diagnostic dump text
- diagnostic load_arrays
- diagnostic moderation set count
- diagnostic moderation set timer
- diagnostic moderation show count
- diagnostic moderation show timer
- diagnostic set boot_parameter
- diagnostic show boot_parameter
- diagnostic show history
- logfile Commands
- task Commands
- enclosure Commands
- enclosure activate slot
- enclosure identify slot
- enclosure list
- enclosure prepare slot
- enclosure set alarm
- enclosure set door
- enclosure set fan
- enclosure set interval
- enclosure set power
- enclosure set scsiid
- enclosure set temperature
- enclosure show fan
- enclosure show power
- enclosure show slot
- enclosure show status
- enclosure show temperature
- Automated Scripts
- Reference Guide

5-14
disk Commands
Specifies whether to enable S.M.A.R.T. configurations (enable
exception reporting) for all disks on the system. If you specify
TRUE for this switch, the command enables S.M.A.R.T.
configurations for all disks on the system.
The default is FALSE; the disk set smart command does
not enable S.M.A.R.T. configurations for all disks on the
system. In this case, you would want to specify a SCSI ID to
enable S.M.A.R.T. configurations for a specific disk on the
system.
/clear{=boolean}
Specifies whether to clear S.M.A.R.T. error counts for the
specified disk or disks. If you specify TRUE for this switch, the
command clears error counts for the specified disk or disks.
The default is FALSE; that is, the disk set smart
command does not clear S.M.A.R.T. error counts for disks on
the system.
/enable_exceptions{=boolean}
Specifies whether to enable S.M.A.R.T. exceptions reporting
for the specified disk or disks. If you specify TRUE for this
switch, the command enables exception reporting for the
specified disk or disks.
The default is FALSE; that is, the disk set smart
command does not enable S.M.A.R.T. exception reporting for
disks on the system.
/interval_timer{=integer} <?>
/logerr{=boolean}
Specifies whether to enable logging of S.M.A.R.T. exception
reporting for the specified disk or disks. If you specify TRUE
for this switch, the command enables logging of S.M.A.R.T.
exception reporting for the specified disk or disks.
If you specify FALSE for this switch, the command disables
logging of S.M.A.R.T. exception reporting for the specified
disk or disks.