Installation guide
Table Of Contents
- Command Line Interface
- Reference Guide
- Introduction
- General Control Commands
- container Commands
- container add_level
- container create mirror
- container create mmirror
- container create mstripe
- container create mvolume
- container create raid5
- container create stripe
- container create volume
- container delete
- container extend file_system
- container extend mvolume
- container extend volume
- container list
- container lock
- container move
- container promote
- container readonly
- container readwrite
- container reconfigure
- container release_cache
- container remove drive_letter
- container remove failover
- container remove file_system
- container remove global_failover
- container restore RAID5
- container scrub
- container set cache
- container set failover
- container set global_failover
- container set io_delay
- container set label
- container show cache
- container show failover
- container split
- container unlock
- container unmirror
- controller Commands
- controller details
- controller firmware compare
- controller firmware save
- controller firmware update
- controller list
- controller pause_io
- controller rescan
- controller reset_scsi_channel
- controller resume_io
- controller set automatic_failover
- controller set array_verify
- controller show automatic_failover
- controller show channels
- controller show array_verify
- disk Commands
- diagnostic Commands
- diagnostic clear boot_parameters
- diagnostic dump structures
- diagnostic dump text
- diagnostic load_arrays
- diagnostic moderation set count
- diagnostic moderation set timer
- diagnostic moderation show count
- diagnostic moderation show timer
- diagnostic set boot_parameter
- diagnostic show boot_parameter
- diagnostic show history
- logfile Commands
- task Commands
- enclosure Commands
- enclosure activate slot
- enclosure identify slot
- enclosure list
- enclosure prepare slot
- enclosure set alarm
- enclosure set door
- enclosure set fan
- enclosure set interval
- enclosure set power
- enclosure set scsiid
- enclosure set temperature
- enclosure show fan
- enclosure show power
- enclosure show slot
- enclosure show status
- enclosure show temperature
- Automated Scripts
- Reference Guide

5-20
disk Commands
The Array Num and Array Type Columns
The Array Num column displays the ID of the primary array in
the partition. In the example, the array ID is 0.
The Array Type column displays the type of array in which the
partition resides. Table 5-3 lists the possible values that the
command can display in the Type column.
Table 5-3 Primary Array Values
The MultiLevel Num and MultiLevel Type Columns
The MultiLevel Num column displays the ID of the multilevel
array the partition is associated with (if any). In the example, the
array ID is 0.
The MultiLevel Type column displays the type of multilevel array
in which the partition resides. Table 5-4 lists the possible values
that the command can display in the Type column.
Table 5-4 Multilevel Array Values
Value Meaning
None This partition is not in an array.
Mirror This partition is part of a mirror set.
Stripe This partition is part of a stripe set.
Volume This partition is part of a volume set.
RAID-5 This partition is part of a RAID 5 array.
Reconf This partition is part of an array reconfiguration operation.
An array reconfiguration operation occurs when you use
the
array reconfigure command to change an array
from one type to another. The Reconf value is not used in
UNIX.
Value Meaning
None This partition is not in a secondary array.
Stripe This partition is part of a stripe set.