Installation guide
Table Of Contents
- Command Line Interface
- Reference Guide
- Introduction
 - General Control Commands
 - container Commands
- container add_level
 - container create mirror
 - container create mmirror
 - container create mstripe
 - container create mvolume
 - container create raid5
 - container create stripe
 - container create volume
 - container delete
 - container extend file_system
 - container extend mvolume
 - container extend volume
 - container list
 - container lock
 - container move
 - container promote
 - container readonly
 - container readwrite
 - container reconfigure
 - container release_cache
 - container remove drive_letter
 - container remove failover
 - container remove file_system
 - container remove global_failover
 - container restore RAID5
 - container scrub
 - container set cache
 - container set failover
 - container set global_failover
 - container set io_delay
 - container set label
 - container show cache
 - container show failover
 - container split
 - container unlock
 - container unmirror
 
 - controller Commands
- controller details
 - controller firmware compare
 - controller firmware save
 - controller firmware update
 - controller list
 - controller pause_io
 - controller rescan
 - controller reset_scsi_channel
 - controller resume_io
 - controller set automatic_failover
 - controller set array_verify
 - controller show automatic_failover
 - controller show channels
 - controller show array_verify
 
 - disk Commands
 - diagnostic Commands
- diagnostic clear boot_parameters
 - diagnostic dump structures
 - diagnostic dump text
 - diagnostic load_arrays
 - diagnostic moderation set count
 - diagnostic moderation set timer
 - diagnostic moderation show count
 - diagnostic moderation show timer
 - diagnostic set boot_parameter
 - diagnostic show boot_parameter
 - diagnostic show history
 
 - logfile Commands
 - task Commands
 - enclosure Commands
- enclosure activate slot
 - enclosure identify slot
 - enclosure list
 - enclosure prepare slot
 - enclosure set alarm
 - enclosure set door
 - enclosure set fan
 - enclosure set interval
 - enclosure set power
 - enclosure set scsiid
 - enclosure set temperature
 - enclosure show fan
 - enclosure show power
 - enclosure show slot
 - enclosure show status
 - enclosure show temperature
 
 - Automated Scripts
 
 
 - Reference Guide
 

5-24
disk Commands
The C:ID:L Column
The C:ID:L column displays the SCSI channel number, the SCSI 
device ID, and the SCSI device logical unit number for each disk on 
the currently opened controller. (The display shows only one disk 
if you specified a particular disk.)
In the example, the command displays the SCSI channel number, 
the SCSI device ID, and the SCSI device logical unit number for the 
four disks on the open controller.
The Smart Capable Device Column
The Smart Capable Device column displays the value Y if the 
device is S.M.A.R.T. capable or the value N if the device is not 
S.M.A.R.T. capable.
The Method of Informational Exceptions (MRIE) Column <?>
The Method of Informational Exceptions (MRIE) column displays 
the MRIE value (one of a possible six values). However, you cannot 
set the MRIE. Your devices report exceptions only when polled 
(level 6) and you cannot change the setting for this switch.
The Enable Exception Control Column
The Enable Exception Control column displays the value Y if you 
enabled S.M.A.R.T. exception control reporting or the value N if 
you did not enable S.M.A.R.T. exception control reporting.
If you specified the /view_changeable switch, the command 
displays an X in this column for those disks on which you can 
enable S.M.A.R.T. exception control reporting.
The Performance Enabled Column
The Performance Enabled column displays the value Y if you 
enabled performance or N if you did not enable performance. You 
enable performance by using the disk set smart command’s /
perf switch.
If you specified the /view_changeable switch, the command 
displays an X in this column for those disks on which you can 
enable performance.