Installation guide
Table Of Contents
- Command Line Interface
- Reference Guide
- Introduction
 - General Control Commands
 - container Commands
- container add_level
 - container create mirror
 - container create mmirror
 - container create mstripe
 - container create mvolume
 - container create raid5
 - container create stripe
 - container create volume
 - container delete
 - container extend file_system
 - container extend mvolume
 - container extend volume
 - container list
 - container lock
 - container move
 - container promote
 - container readonly
 - container readwrite
 - container reconfigure
 - container release_cache
 - container remove drive_letter
 - container remove failover
 - container remove file_system
 - container remove global_failover
 - container restore RAID5
 - container scrub
 - container set cache
 - container set failover
 - container set global_failover
 - container set io_delay
 - container set label
 - container show cache
 - container show failover
 - container split
 - container unlock
 - container unmirror
 
 - controller Commands
- controller details
 - controller firmware compare
 - controller firmware save
 - controller firmware update
 - controller list
 - controller pause_io
 - controller rescan
 - controller reset_scsi_channel
 - controller resume_io
 - controller set automatic_failover
 - controller set array_verify
 - controller show automatic_failover
 - controller show channels
 - controller show array_verify
 
 - disk Commands
 - diagnostic Commands
- diagnostic clear boot_parameters
 - diagnostic dump structures
 - diagnostic dump text
 - diagnostic load_arrays
 - diagnostic moderation set count
 - diagnostic moderation set timer
 - diagnostic moderation show count
 - diagnostic moderation show timer
 - diagnostic set boot_parameter
 - diagnostic show boot_parameter
 - diagnostic show history
 
 - logfile Commands
 - task Commands
 - enclosure Commands
- enclosure activate slot
 - enclosure identify slot
 - enclosure list
 - enclosure prepare slot
 - enclosure set alarm
 - enclosure set door
 - enclosure set fan
 - enclosure set interval
 - enclosure set power
 - enclosure set scsiid
 - enclosure set temperature
 - enclosure show fan
 - enclosure show power
 - enclosure show slot
 - enclosure show status
 - enclosure show temperature
 
 - Automated Scripts
 
 
 - Reference Guide
 

8-3
task Commands
As the example shows, the typical display shows the following 
columns of information:
■ TaskId
■ Function
■ Done%
■ Array
■ State
■ Specific1
■ Specific2
The following sections describe each column that the task list 
command displays.
The Task ID Column
The Task ID  column displays the ID number associated with a 
specific task. The controller assigns each task a unique ID number.
The Function Column
The Function column displays the type of task running on the 
controller. Table 8-1 describes the types of tasks that the task 
list command can display.
Ta bl e  8 -1 Ta s k  Types
Task Type Meaning
Create A create mirror set or create multilevel mirror set task is 
running on the specified array. When the create mirror set 
or create multilevel mirror set task completes, the specified 
array is a mirror set or a multilevel array of mirror sets. The 
create a mirror set or create a multilevel mirror set task runs 
as a result of using the 
array create mirror or 
array create mmirror command.
FATfmt An array format FAT file system task is running on the 
specified array. The format FAT file system task runs as a 
result of using the 
array format command with the /
file_system
 switch set to FAT.