Installation guide
Table Of Contents
- Command Line Interface
- Reference Guide
- Introduction
 - General Control Commands
 - container Commands
- container add_level
 - container create mirror
 - container create mmirror
 - container create mstripe
 - container create mvolume
 - container create raid5
 - container create stripe
 - container create volume
 - container delete
 - container extend file_system
 - container extend mvolume
 - container extend volume
 - container list
 - container lock
 - container move
 - container promote
 - container readonly
 - container readwrite
 - container reconfigure
 - container release_cache
 - container remove drive_letter
 - container remove failover
 - container remove file_system
 - container remove global_failover
 - container restore RAID5
 - container scrub
 - container set cache
 - container set failover
 - container set global_failover
 - container set io_delay
 - container set label
 - container show cache
 - container show failover
 - container split
 - container unlock
 - container unmirror
 
 - controller Commands
- controller details
 - controller firmware compare
 - controller firmware save
 - controller firmware update
 - controller list
 - controller pause_io
 - controller rescan
 - controller reset_scsi_channel
 - controller resume_io
 - controller set automatic_failover
 - controller set array_verify
 - controller show automatic_failover
 - controller show channels
 - controller show array_verify
 
 - disk Commands
 - diagnostic Commands
- diagnostic clear boot_parameters
 - diagnostic dump structures
 - diagnostic dump text
 - diagnostic load_arrays
 - diagnostic moderation set count
 - diagnostic moderation set timer
 - diagnostic moderation show count
 - diagnostic moderation show timer
 - diagnostic set boot_parameter
 - diagnostic show boot_parameter
 - diagnostic show history
 
 - logfile Commands
 - task Commands
 - enclosure Commands
- enclosure activate slot
 - enclosure identify slot
 - enclosure list
 - enclosure prepare slot
 - enclosure set alarm
 - enclosure set door
 - enclosure set fan
 - enclosure set interval
 - enclosure set power
 - enclosure set scsiid
 - enclosure set temperature
 - enclosure show fan
 - enclosure show power
 - enclosure show slot
 - enclosure show status
 - enclosure show temperature
 
 - Automated Scripts
 
 
 - Reference Guide
 

9-10
enclosure Commands
Specifically, the column can display the items listed in Table 9-2.
Table 9-2  Diagnostic Status
The EnclosureId, VendorId, and ProductId Columns
The EnclosureId column displays an identification number that is 
unique for each enclosure management device product sold by a 
particular manufacturer.
The VendorId column displays a string that identifies the 
manufacturer of the enclosure management device. In the example, 
the string that identifies the manufacturer of enclosure 
management devices 0 and 1 is ESG-SHV.
The ProductId column displays a string that identifies the 
enclosure management device’s product ID. In the example, the 
product ID for enclosure management devices 0 and 1 is SCA 
HSBP M2.
The Firmware Column
The Firmware column displays the current firmware revision of 
the enclosure management device. In the example, the firmware 
revision for enclosure management devices 0 and 1 is 0.14.
Related Commands
enclosure commands: 
■ enclosure show fan (page 9-26)
■ enclosure show power (page 9-29)
■ enclosure show slot (page 9-32)
■ enclosure show status (page 9-36)
■ enclosure show temperature (page 9-41)
Status Meaning
PASSED No errors were detected and the diagnostic self-tests 
were successful. This is the value displayed in the 
example for both enclosure management devices.
FAILED Errors were detected and the diagnostic self-tests were 
not successful.
UNKNOWN The status of the diagnostic self-tests is unknown.