Installation guide
Table Of Contents
- Command Line Interface
- Reference Guide
- Introduction
- General Control Commands
- container Commands
- container add_level
- container create mirror
- container create mmirror
- container create mstripe
- container create mvolume
- container create raid5
- container create stripe
- container create volume
- container delete
- container extend file_system
- container extend mvolume
- container extend volume
- container list
- container lock
- container move
- container promote
- container readonly
- container readwrite
- container reconfigure
- container release_cache
- container remove drive_letter
- container remove failover
- container remove file_system
- container remove global_failover
- container restore RAID5
- container scrub
- container set cache
- container set failover
- container set global_failover
- container set io_delay
- container set label
- container show cache
- container show failover
- container split
- container unlock
- container unmirror
- controller Commands
- controller details
- controller firmware compare
- controller firmware save
- controller firmware update
- controller list
- controller pause_io
- controller rescan
- controller reset_scsi_channel
- controller resume_io
- controller set automatic_failover
- controller set array_verify
- controller show automatic_failover
- controller show channels
- controller show array_verify
- disk Commands
- diagnostic Commands
- diagnostic clear boot_parameters
- diagnostic dump structures
- diagnostic dump text
- diagnostic load_arrays
- diagnostic moderation set count
- diagnostic moderation set timer
- diagnostic moderation show count
- diagnostic moderation show timer
- diagnostic set boot_parameter
- diagnostic show boot_parameter
- diagnostic show history
- logfile Commands
- task Commands
- enclosure Commands
- enclosure activate slot
- enclosure identify slot
- enclosure list
- enclosure prepare slot
- enclosure set alarm
- enclosure set door
- enclosure set fan
- enclosure set interval
- enclosure set power
- enclosure set scsiid
- enclosure set temperature
- enclosure show fan
- enclosure show power
- enclosure show slot
- enclosure show status
- enclosure show temperature
- Automated Scripts
- Reference Guide

9-15
enclosure Commands
enclosure set fan
To set the speed of a specific fan on a specific SAF-TE enclosure
management device, use the enclosure set fan command.
Syntax
enclosure set fan [/off{=boolean}] {enclosure}
{fan} [{speed}]
Parameters
{enclosure}
Specifies the ID associated with the enclosure management
device on which you want to set the speed of a specific fan.
For this version, the controller supports a maximum of eight
enclosure management devices on each bus.
{fan}
Specifies the unit number associated with the fan whose
speed you want to set. The unit number for the fan ranges
from 0 to 15 inclusive.
{speed}
Specifies the speed at which you want to set this fan. Table 9-3
lists the fan speed values you can specify.
Table 9-3 Fan Speed Values
The fan speed defaults to full speed.
Value Meaning
0 Turns off the fan
1 Runs the fan at 1/4 the full speed.
2 Runs the fan at 1/2 the full speed.
3 Runs the fan at 3/4 the full speed.
4 Runs the fan at full speed.