Installation guide
Table Of Contents
- Command Line Interface
- Reference Guide
- Introduction
- General Control Commands
- container Commands
- container add_level
- container create mirror
- container create mmirror
- container create mstripe
- container create mvolume
- container create raid5
- container create stripe
- container create volume
- container delete
- container extend file_system
- container extend mvolume
- container extend volume
- container list
- container lock
- container move
- container promote
- container readonly
- container readwrite
- container reconfigure
- container release_cache
- container remove drive_letter
- container remove failover
- container remove file_system
- container remove global_failover
- container restore RAID5
- container scrub
- container set cache
- container set failover
- container set global_failover
- container set io_delay
- container set label
- container show cache
- container show failover
- container split
- container unlock
- container unmirror
- controller Commands
- controller details
- controller firmware compare
- controller firmware save
- controller firmware update
- controller list
- controller pause_io
- controller rescan
- controller reset_scsi_channel
- controller resume_io
- controller set automatic_failover
- controller set array_verify
- controller show automatic_failover
- controller show channels
- controller show array_verify
- disk Commands
- diagnostic Commands
- diagnostic clear boot_parameters
- diagnostic dump structures
- diagnostic dump text
- diagnostic load_arrays
- diagnostic moderation set count
- diagnostic moderation set timer
- diagnostic moderation show count
- diagnostic moderation show timer
- diagnostic set boot_parameter
- diagnostic show boot_parameter
- diagnostic show history
- logfile Commands
- task Commands
- enclosure Commands
- enclosure activate slot
- enclosure identify slot
- enclosure list
- enclosure prepare slot
- enclosure set alarm
- enclosure set door
- enclosure set fan
- enclosure set interval
- enclosure set power
- enclosure set scsiid
- enclosure set temperature
- enclosure show fan
- enclosure show power
- enclosure show slot
- enclosure show status
- enclosure show temperature
- Automated Scripts
- Reference Guide

9-17
enclosure Commands
enclosure set interval
To set the monitor reporting interval for a specific SAF-TE
enclosure management device, use the enclosure set
interval command. The monitor reporting interval indicates
how often the controller checks the status of the enclosure
management device and its associated components. In setting this
value, consider the needs of your computing environment. Setting
the monitor reporting level to less than ten seconds could cause
slower system performance.
Syntax
enclosure set interval {second}
Parameters
{second}
Specifies the number of seconds for the monitor reporting
interval. You can specify 1 to n seconds where n represents
the number of seconds for the monitor reporting interval.
(The maximum value is 86,400, the number of seconds in a
day.)
The default is 10 seconds.
Examples
Before setting the monitor reporting interval, you might want to
use the enclosure show status command to determine the
current monitor reporting interval setting.
As the following example shows, the current monitor reporting
interval setting is 10:
AAC0>enclosure show status
Enclosure UpTime D:H:M PowerCycle Interval Door Alarm
--------- -------------- ---------- -------- -------- -------
0 0:00:00 0 10 UNLOCKED OFF
.
.
.
Enclosure UpTime D:H:M PowerCycle Interval Door Alarm
--------- -------------- ---------- -------- -------- -------
1 0:00:00 0 10 UNLOCKED OFF