Installation guide
Table Of Contents
- Command Line Interface
- Reference Guide
- Introduction
 - General Control Commands
 - container Commands
- container add_level
 - container create mirror
 - container create mmirror
 - container create mstripe
 - container create mvolume
 - container create raid5
 - container create stripe
 - container create volume
 - container delete
 - container extend file_system
 - container extend mvolume
 - container extend volume
 - container list
 - container lock
 - container move
 - container promote
 - container readonly
 - container readwrite
 - container reconfigure
 - container release_cache
 - container remove drive_letter
 - container remove failover
 - container remove file_system
 - container remove global_failover
 - container restore RAID5
 - container scrub
 - container set cache
 - container set failover
 - container set global_failover
 - container set io_delay
 - container set label
 - container show cache
 - container show failover
 - container split
 - container unlock
 - container unmirror
 
 - controller Commands
- controller details
 - controller firmware compare
 - controller firmware save
 - controller firmware update
 - controller list
 - controller pause_io
 - controller rescan
 - controller reset_scsi_channel
 - controller resume_io
 - controller set automatic_failover
 - controller set array_verify
 - controller show automatic_failover
 - controller show channels
 - controller show array_verify
 
 - disk Commands
 - diagnostic Commands
- diagnostic clear boot_parameters
 - diagnostic dump structures
 - diagnostic dump text
 - diagnostic load_arrays
 - diagnostic moderation set count
 - diagnostic moderation set timer
 - diagnostic moderation show count
 - diagnostic moderation show timer
 - diagnostic set boot_parameter
 - diagnostic show boot_parameter
 - diagnostic show history
 
 - logfile Commands
 - task Commands
 - enclosure Commands
- enclosure activate slot
 - enclosure identify slot
 - enclosure list
 - enclosure prepare slot
 - enclosure set alarm
 - enclosure set door
 - enclosure set fan
 - enclosure set interval
 - enclosure set power
 - enclosure set scsiid
 - enclosure set temperature
 - enclosure show fan
 - enclosure show power
 - enclosure show slot
 - enclosure show status
 - enclosure show temperature
 
 - Automated Scripts
 
 
 - Reference Guide
 

9-33
enclosure Commands
Examples
The following example displays the status of all device slots on 
enclosure management devices 0 and 1:
AAC0>enclosure show slot
Executing: enclosure show slot
Enclosure Slot scsiId Insert  Status      
--------- ---- ------ ------- -----------------------------------
0 0 0:00:0 4 OK
 0 1 0:01:0 0 UNCONFIG 
 0 2 0:10:0 0 UNCONFIG 
 0 3 0:03:0 0 UNCONFIG 
 0 4 0:04:0 0 UNCONFIG 
 1 0 1:00:0 0 UNCONFIG 
 1 1 1:01:0 0 UNCONFIG 
 1 2 1:10:0 0 UNCONFIG 
 1 3 1:03:0 0 UNCONFIG 
 1 4 1:04:0 0 UNCONFIG
As the example shows, the device slot status display contains the 
following columns:
■ Enclosure
■ Slot
■ scsiId
■ Insert
■ Status
The following sections describe the information that the 
enclosure show slot command can display in these columns.
The Enclosure and Slot Columns
The Enclosure column displays the ID associated with the 
enclosure management device that you specified on the command 
line. If you did not specify an ID, the enclosure show slot 
command displays the IDs for all enclosure management devices 
connected to the controller. In the example, the enclosure show 
slot command displays enclosure management device IDs 0 and 
1.
The Slot column displays the unit number associated with the 
device slot that you specified on the command line. If you did not 
specify a unit number, the enclosure show slot command 
displays the unit numbers for all device slots on the enclosure 
management device or devices. In the example, the enclosure 
show slot command displays the device slot status for device 
slots 0 through 4 for enclosure management devices 0 and 1.