Installation guide
Table Of Contents
- Command Line Interface
- Reference Guide
- Introduction
 - General Control Commands
 - container Commands
- container add_level
 - container create mirror
 - container create mmirror
 - container create mstripe
 - container create mvolume
 - container create raid5
 - container create stripe
 - container create volume
 - container delete
 - container extend file_system
 - container extend mvolume
 - container extend volume
 - container list
 - container lock
 - container move
 - container promote
 - container readonly
 - container readwrite
 - container reconfigure
 - container release_cache
 - container remove drive_letter
 - container remove failover
 - container remove file_system
 - container remove global_failover
 - container restore RAID5
 - container scrub
 - container set cache
 - container set failover
 - container set global_failover
 - container set io_delay
 - container set label
 - container show cache
 - container show failover
 - container split
 - container unlock
 - container unmirror
 
 - controller Commands
- controller details
 - controller firmware compare
 - controller firmware save
 - controller firmware update
 - controller list
 - controller pause_io
 - controller rescan
 - controller reset_scsi_channel
 - controller resume_io
 - controller set automatic_failover
 - controller set array_verify
 - controller show automatic_failover
 - controller show channels
 - controller show array_verify
 
 - disk Commands
 - diagnostic Commands
- diagnostic clear boot_parameters
 - diagnostic dump structures
 - diagnostic dump text
 - diagnostic load_arrays
 - diagnostic moderation set count
 - diagnostic moderation set timer
 - diagnostic moderation show count
 - diagnostic moderation show timer
 - diagnostic set boot_parameter
 - diagnostic show boot_parameter
 - diagnostic show history
 
 - logfile Commands
 - task Commands
 - enclosure Commands
- enclosure activate slot
 - enclosure identify slot
 - enclosure list
 - enclosure prepare slot
 - enclosure set alarm
 - enclosure set door
 - enclosure set fan
 - enclosure set interval
 - enclosure set power
 - enclosure set scsiid
 - enclosure set temperature
 - enclosure show fan
 - enclosure show power
 - enclosure show slot
 - enclosure show status
 - enclosure show temperature
 
 - Automated Scripts
 
 
 - Reference Guide
 

9-37
enclosure Commands
Examples
The following example displays status information for enclosure 
management devices 0 and 1:
AAC0>enclosure show status
Executing: enclosure show status
Enclosure UpTime D:H:M PowerCycle Interval Door Alarm 
--------- -------------- ---------- -------- -------- ------- 
 0 0:04:25 2 20 UNLOCKED OFF
Enclosure Fan Status 
--------- --- -------------
 0 0 OK
Enclosure Power State Status 
--------- ----- ------------ -------
 0 0 UNKNOWN UNKNOWN
Enclosure Slot scsiId Insert  Status      
--------- ---- ------ ------- ----------------------------------------
--
 0 0 0:00:0 0 OK UNCONFIG ACTIVATE
 0 1 0:01:0 0 OK UNCONFIG ACTIVATE
 0 2 0:10:0 0 OK UNCONFIG ACTIVATE 
 0 3 0:03:0 0 OK UNCONFIG ACTIVATE 
 0 4 0:04:0 0 OK UNCONFIG ACTIVATE
Enclosure Sensor Temperature Threshold Status 
--------- ------ ----------- --------- -------- 
 0 0 72 F 120 NORMAL
Enclosure UpTime D:H:M PowerCycle Interval Door Alarm 
--------- -------------- ---------- -------- -------- ------- 
 1 2:20:25 3 20 UNLOCKED OFF
Enclosure Fan Status 
--------- --- -------------
 1 0 NOT INSTALLED
Enclosure Power State Status 
--------- ----- ------------ -------
 1 0 UNKNOWN UNKNOWN
Enclosure Slot scsiId Insert  Status      
--------- ---- ------ ------- ----------------------------------------
--
 1 0 1:00:0 0 UNCONFIG 
 1 1 1:01:0 0 UNCONFIG 
 1 2 1:10:0 0 UNCONFIG 
 1 3 1:03:0 0 UNCONFIG 
 1 4 1:04:0 0 UNCONFIG 
Enclosure Sensor Temperature Threshold Status 
--------- ------ ----------- --------- -------- 
 1 0 75 F 120 NORMAL 