Installation guide
Table Of Contents
- Command Line Interface
- Reference Guide
- Introduction
 - General Control Commands
 - container Commands
- container add_level
 - container create mirror
 - container create mmirror
 - container create mstripe
 - container create mvolume
 - container create raid5
 - container create stripe
 - container create volume
 - container delete
 - container extend file_system
 - container extend mvolume
 - container extend volume
 - container list
 - container lock
 - container move
 - container promote
 - container readonly
 - container readwrite
 - container reconfigure
 - container release_cache
 - container remove drive_letter
 - container remove failover
 - container remove file_system
 - container remove global_failover
 - container restore RAID5
 - container scrub
 - container set cache
 - container set failover
 - container set global_failover
 - container set io_delay
 - container set label
 - container show cache
 - container show failover
 - container split
 - container unlock
 - container unmirror
 
 - controller Commands
- controller details
 - controller firmware compare
 - controller firmware save
 - controller firmware update
 - controller list
 - controller pause_io
 - controller rescan
 - controller reset_scsi_channel
 - controller resume_io
 - controller set automatic_failover
 - controller set array_verify
 - controller show automatic_failover
 - controller show channels
 - controller show array_verify
 
 - disk Commands
 - diagnostic Commands
- diagnostic clear boot_parameters
 - diagnostic dump structures
 - diagnostic dump text
 - diagnostic load_arrays
 - diagnostic moderation set count
 - diagnostic moderation set timer
 - diagnostic moderation show count
 - diagnostic moderation show timer
 - diagnostic set boot_parameter
 - diagnostic show boot_parameter
 - diagnostic show history
 
 - logfile Commands
 - task Commands
 - enclosure Commands
- enclosure activate slot
 - enclosure identify slot
 - enclosure list
 - enclosure prepare slot
 - enclosure set alarm
 - enclosure set door
 - enclosure set fan
 - enclosure set interval
 - enclosure set power
 - enclosure set scsiid
 - enclosure set temperature
 - enclosure show fan
 - enclosure show power
 - enclosure show slot
 - enclosure show status
 - enclosure show temperature
 
 - Automated Scripts
 
 
 - Reference Guide
 

3-52
container Commands
This column also displays the label assigned to the array when the 
array was created. If no label was assigned to the array then no 
label appears in the column. You can assign labels with the 
following commands:
■ container create mstripe
■ container create mvolume
■ container create raid5
■ container create stripe
■ container create volume
■ container set label
If your controller is running on a UNIX operating system, then the 
Num Label column also displays a root special file. On UNIX 
systems, arrays are associated with root special files not drive 
letters.
See your UNIX documentation for information on how to mount 
the array or to create a file system.
The Type Column
This column displays the type of array. Table 3-1 describes the type 
values that can display in the Type column.
The CLI automatically assigns the array type as a result of creating 
arrays with the container create-related commands.
The CLI assigns the array type Reconf
 when the array is 
reconfigured from one array type to another. The container 
reconfigure
 command provides switches that allow you to 
reconfigure an array into specific array types.
Table 3-1 Container Types
container Type Meaning
Mirror
The container is a mirror set.
Stripe
The container is a stripe set.
Volume
The container is a volume set.
RAID-5
The container is a RAID 5 array.
Reconf
The container was reconfigured.