Analogue Output Card Installation Instruction
This assembly and desk contain static sensitive components.
Installation should be undertaken using appropriate precautions.
Turn the desk over onto it ' s front and remove the rear cover plate. Put this and the
screws carefully to one side, to refit later.
Using a sharp scalpel, or similar, cut out either one or both of the analogue output
connector positions in the rear connector panel of the control desk. Make sure the
scalpel blade is kept tight against the metal chassis to ensure a clean cut edge is
achieved.
Carefully remove the analogue output card from it’s anti-static protective bag.
Remove the small hexagonal screws in the front face of the twenty five way output
connectors and put carefully to one side.
The analogue board is normally configured as voltage driven outputs (0 to +10V). If you
wish to configure it as current driven outputs (0 to 370µA), you must replace the 120
resistors by the 27K resistors, delivered with the board, as 16-contact chips (DIL's)
Hold the analogue board upside down, i.e. with the components facing the table top
and the flying lead running under the board.Insert the output connector(s) through the
cut-out(s) in the rear connector panel and push the two plastic support pillars firmly
through the two mating holes in the main board in the desk.
The pillars should snap into place.
The small hexagonal screws removed earlier can now be screwed back into the output
connector(s), through the rear panel, to hold the board securely in place.
Plug the flying lead connector into the ten way header on the master board.
Replace the rear cover.
Selectional view of output board fitted into desk
Plastic rivets
Analogue board
Metal chassis
Hexagonal screws
Output connector(s)
Main board
Support pillars