Service manual

Motorised Yoke
Service Manual - page 44 www.adblighting.com
Issue 0.9
7.7 Change Motor Board Right
Required Tool(s) Spare Part Code Preliminary reading
Flat Screwdriver
Wire Cutter
1001.65.220
Chapter 7.1
Chapter 6.1
1. Switch OFF and Unplug the WARP
2. Disconnect from the Board: WARP Link 1 - WARP Link 2 - Magnetic Sensor – XLR 4
3. Disconnect all motors and cut cable tie on the heat sink
4. Remove the 4 screws
5. Replace Right 6 Drivers Board (use new cable tie)
1001.65.220
1001.65.220 includes:
1 Complete right
Board
5 Screws M3*8
5 Washers
3 cable ties
MOTOR LABELS
R4 R5 R6 R3 R2 R1
M1 M2 M3 M4 M5 M6
Important:
Before switch on, remove accessories
(iris, gobo, …)
When you restart; all rings will calibrate