Interwave Wave2000 BSS Specification Printed 11/21/02 12:29 PM
Interwave Wave2000 BSS Specification.docInterwave Proprietary Information 24 of 32
host name : host
file name : D:/tornado2/target/config/vssbsp/chc/vxWorks.st
inet on ethernet (e) : 192.168.1.34
host inet (h) : 192.168.1.125
gateway inet (g) : 192.168.1.1
user (u) : target
ftp password (pw) : target
flags (f) : 0x0
target name (tn) : Chc66Mhz
other (o) : cpm
Figure 8-12 vxWorks boot parameters in CHC
Step 3:
To change the boot parameters type “c” at the boot prompt, as follows:
[vxWorks Boot]: c
boot device : tffs=0,00 _
If a particular field has the correct value already, press “ENTER”. To clear a field, enter a period(.), then
press “ENTER”. If you want to quit before completing all the parameters, type CTRL+D. Or simply press
“ENTER” all the way to the end of the table.
Basically, for a new system, the following parameters need to be changed:
“file name” (the directory and path of the application image in the PC)
“inet on ethernet” (scon/chc ip address)
host inet” (host computer ip address)
“gateway inet” (local network gateway)
Other parameters should be kept the same. In some case, the user and ftp password have to be set also.
Step 4:
After the change, boot the system using the current boot parameters by typing “@” at the boot prompt or
simple reboot the system.
[vxWork Boot]: @
Remarks:
In case of failing in booting up the vxWorks, check the Host IP address and the location of the application image file in the PC
terminal. Also, the cable connection may also cause the problem.
1.1.2 5.3.2 Application system configuration
Secondly, configure the application system parameters in SCON. After the vxWorks operating system
booting up, there should be an arrow prompt ->” on the SCON console. At the prompt, type
“showConfig” to the following manual:
->showConfig
System Configuration Menu
1 - BSC Parameters.
2 - BTS Parameters.