User's Manual

Interwave Wave2000 BSS Specification Printed 11/21/02 12:29 PM
Interwave Wave2000 BSS Specification.docInterwave Proprietary Information 27 of 32
52:rfSubSystemGain = 24
53:pcsMode = 1
Press ENTER to quit, c to change parameter.
value = 0 = 0x0
->
Figure 8-15 BTS paramaters manual
Change the following parameters according to the system setting:
01. SID System ID
02. NID Network ID
05. freq Channel frequency used
06. cdmaTrasPower Pilot transmit power. (from 26dBm to 36dBm)
52. pcsMode 1 = PCS, 0 = Cellular
The rest of the parameters are not necessary to change at this moment, default values is good enough for the
system.
After finishing the system parameter setup, the application software can be executed by entering
“interwaveSconEntry” at the SCON console prompt and “interwaveChcEntry” at the CHC console prompt.
Make sure that the SCON application is run up completely first, and then CHC application. If not, the
CHC will be rebooted automatically. After, the mobile phone should be locked to the BSS and ready for
the testing section. For details description about the system configuration, see the reference [6].