118 Link CX User Manual, Version A
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A receiver overload alarm will be generated if the level
of RSSI is at or above -40 dBm. A value of 1 indicates the
received signal level is below -40 dBm. A value of 2 indicates
the received signal level is at or above -40 dBm.
This alarm is only valid if the Rx synthesizer is locked."
::= }link_cx_status 10}
bitErrorRateAlarmStatus OBJECT-TYPE -- link alarm condition
SYNTAX INTEGER {
normal(1),
alarm(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A bit error rate alarm will be generated if the level
of BER is at or above 10^-3, i.e. if bitErrorRate is
equal to or greater than 100000."
::= }link_cx_status 11}
-- link_cx_test group
rfTxAttenuateTimer OBJECT-TYPE
SYNTAX INTEGER (0..1800)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"To temporarily enable Tx attenuation by 40 dB, write the number of
seconds to this timer. When the timer counts down to 0, Tx attenuation
will return to its normal unattenuated state. Writing to this timer
has no effect if rfTxAttenuateControl is set to enable because in
that case the transmitter is already attenuated."
::= }link_cx_test 1}
ds3LocalLoopbackControl OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The DS3 local loopback control. When enabled, DS3 data on the
local interface is looped back through the local interface.
When disabled, DS3 data on the local interface is sent over
the radio link to the remote unit."
::= }link_cx_test 2}