User's Manual Part 6

E-6 Appendix E Alarm Report Monitor (ARM2000)
J6 Alarms 11,12 Main Hub 6
J7 Alarms 13,14 Main Hub 7
J8 Alarms 15,16 Main Hub 8
Input Alarm input to ARM unit
Output Remote Reset from ARM unit
Alarm Cable and Connectors
Test Setup
After the ARM unit is powered up, the unit should be reset and ready for
communicating to the PCARM system for final programing.
When the ARM is powered, wait 15 seconds and then press the TEST button on the
left front of the unit. All 16 circuit alarm LEDs on the front panel should light and
toggle to green momentarily. If this does not occur, power down the ARM unit for
15 seconds and start over.
The LED final state should be green to indicate a proper connection and a no-fault
condition for each Main Hub that is also powered up. Each Main Hub has 2 LEDs
assigned to it. Alarm circuits that do not have an octopus cable connected will be
red.