User's Manual Part 6

E-18 Appendix E Alarm Report Monitor (ARM2000)
Resetting the Main Hub Remotely
The remote-ARM unit is designed not only to monitor the alarm conditions, but also
to reset the Main Hub from a remote site. When an alarm condition occurs, you can
clear the alarm from the PCARM via the control menu and then reset the Main Hub.
To reset an alarm condition remotely
1
From the Device View screen, click Control Menu to go to the Control Panel
screen.
2
Choose a hub to reset by clicking that hub.
PCARM displays the Control Relay dialog box, which gives you the option to
pulse or change the state of the relay.
3
Click Pulse to reset the hub.
PCARM displays the Pulse Duration dialog box, which asks you for a pulse
time and displays the following message:
ONLY ONE (1) SECOND PULSE IS REQUIRED TO RESET THE HUB.