User's Manual Part 6

A-5
Unshielded Twisted Pair Cable Termination
All UTP (Unshielded Twisted Pair) shall be terminated according to the TIA/EIA
568-A standard. The following diagram describes how the four pairs should be
terminated.
The UTP/STP cable can be any length from 10 meters up to 60 meters. (Per
TIA/EIA specifications, UTP/STP cable must be at least 10 meters.) For
cables longer than 60 meters, system specifications are slightly degraded.
When using high quality UTP/STP cable, lengths up to 60 meters can be
used without degrading system performance.
12 3 45 6 78
Brown
Brown/
White
Blue
Blue/
White
Green/
White
Green Orange
Orange/
White
Top View of the Wiring Map for Category 5 (CAT 5) UTP Cable
(TIA/EIA 568-A Standard)
Straight Connect