User's Manual
PN 8100-40 Help Hot Line (U.S. only): 1-800-530-9960 2-13
620004-0 Rev. B
System Specifications
2.4 System Specifications
General system specifications are provided in this section. Specifications for each
component are provided in their respective sections:
• Section 3.4, “LGCell Main Hub Specifications,” on page 3-9
• Section 4.4, “LGCell Expansion Hub Specifications,” on page 4-7
• Section 5.3, “LGCell Remote Access Unit Specifications,” on page 5-5
2.4.1 Environmental Specifications
2.4.2 Physical Specifications
Parameter Rating
Operating Temperature 0° to +45°C / 32° to +113°F
Non-operating Temperature –20° to +85°C / –4° to +185°F
Operating Humidity; non-condensing 5% to 95%
Parameter Main Hub Expansion Hub Remote Access Unit
RF Connectors 3, N-type female 4, RJ-45 1, RJ-45 port
1, SMA female
Remote Alarm
Connector
(contact closure)
1, 9-pin D-sub, female
1, 25-pin D-sub (not used),
male
——
MMF Connectors 4 Pair, ST female 1 Pair, ST female —
LED Alarm and
Status Indicators
Sync, Power, Port Link Status,
Port Sync
Sync, Power, Port Link Status,
Port Sync
Power, Sync
AC Power (Universal)
Typical
Maximum
117V AC, 0.22 amp @ 60 Hz
230V AC, 0.11 amp @ 50 Hz
117V AC, 0.30 amp @ 60 Hz
230V AC, 0.15 amp @ 50 Hz
117V AC, 0.47 amp @ 60 Hz
230V AC, 0.24 amp @ 50 Hz
117V AC, 0.64 amp @ 60 Hz
230V AC, 0.32 amp @ 50 Hz
—
—
Power Consumption
Typical
Maximum
25 W
35 W
32 W / 55 W with 4 RAUs
45 W / 75 W with 4 RAUs
5.7 W
7.5 W
Enclosure Dimensions
(height
× width × depth)
Excluding angle-brack-
ets for 19'' rack mount-
ing of hubs.
44.5 mm
× 438 mm × 229 mm
(1.75 in.
× 17.25 in. × 9 in.)
1U
44.5 mm
× 438 mm × 229 mm
(1.75 in.
× 17.25 in. × 9 in.)
1U
36 mm
× 110 mm × 140 mm
(1.4 in.
× 4.3 in. × 5.5 in.)
Weight < 3 kg (< 6.5 lb) < 3 kg (< 6.5 lb) < 0.4 kg (<1 lb)
MTBF (hours) 298,000 461,000 965,000