2.4 System Specifications
General system specifications are provided in this section. Specifications for each
component are provided in their respective sections:
Section 3.4, “LGCell Main Hub Specifications,” on page 3-9
Section 4.4, “LGCell Expansion Hub Specifications,” on page 4-7
Section 5.3, “LGCell Remote Access Unit Specifications,” on page 5-5
2.4.1 Environmental Specifications
2.4.2 Physical Specifications
Parameter Rating
Operating Temperature 0° to +45°C / 32° to +113°F
Non-operating Temperature –20° to +85°C / –4° to +185°F
Operating Humidity; non-condensing 5% to 95%
Parameter Main Hub Expansion Hub Remote Access Unit
RF Connectors 3, N-type female 4, RJ-45 1, RJ-45 port
1, SMA female
Remote Alarm
Connector
(contact closure)
1, 9-pin D-sub, female
1, 25-pin D-sub (not used),
male
——
MMF Connectors 4 Pair, ST female 1 Pair, ST female
LED Alarm and
Status Indicators
Sync, Power, Port Link Status,
Port Sync
Sync, Power, Port Link Status,
Port Sync
Power, Sync
AC Power (Universal)
Typical
Maximum
117V AC, 0.22 amp @ 60 Hz
230V AC, 0.11 amp @ 50 Hz
117V AC, 0.30 amp @ 60 Hz
230V AC, 0.15 amp @ 50 Hz
117V AC, 0.47 amp @ 60 Hz
230V AC, 0.24 amp @ 50 Hz
117V AC, 0.64 amp @ 60 Hz
230V AC, 0.32 amp @ 50 Hz
Power Consumption
Typical
Maximum
25 W
35 W
32 W / 55 W with 4 RAUs
45 W / 75 W with 4 RAUs
5.7 W
7.5 W
Enclosure Dimensions
(height
× width × depth)
Excluding angle-brack-
ets for 19'' rack mount-
ing of hubs.
44.5 mm
× 438 mm × 229 mm
(1.75 in.
× 17.25 in. × 9 in.)
1U
44.5 mm
× 438 mm × 229 mm
(1.75 in.
× 17.25 in. × 9 in.)
1U
36 mm
× 110 mm × 140 mm
(1.4 in.
× 4.3 in. × 5.5 in.)
Weight < 3 kg (< 6.5 lb) < 3 kg (< 6.5 lb) < 0.4 kg (<1 lb)
MTBF (hours) 298,000 461,000 965,000