User's Manual

PN 8100-40 Help Hot Line (U.S. only): 1-800-530-9960 3-9
620004-0 Rev. B
LGCell Main Hub Specifications
3.4 LGCell Main Hub Specifications
Note that for dual band systems, the specifications are per band.
Table 3-2 Main Hub Specifications
Specification Description
Dimensions (H
× W × D) 44.5 mm × 438 mm × 229 mm (1.75 in. × 17.25 in. × 9 in.); 1U
Weight < 3 kg (< 6.5 lb)
Operating Temperature 0° to 45°C (32° to 113°F)
Operating Humidity, non-condensing 5% to 95%
Clearance Front: minimum 50 mm (2 in.)
Rear: minimum 76 mm (3 in.)
RF Connectors 3, N-type female
Remote Alarm Connector, contact closure 1, 9-pin D-sub female
1, 25-pin D-sub female (not used)
Multimode Fiber Connectors 4 pair, ST female
LED Alarm and Status Indicators MMF Port: Link Status, Sync (4 pair)
Unit Functionality: Sync, Power (1 pair)
AC Power (Universal)
Typical
Maximum
117V AC, 0.22 amp @ 60 Hz
230V AC, 0.11 amp @ 50 Hz
117V AC, 0.30 amp @ 60 Hz
230V AC, 0.15 amp @ 50 Hz
Power Consumption
Typical
Maximum
25 W
35 W
Frequencies 800 MHz AMPS/TDMA/CDMA/iDEN
•900 MHz GSM
•900 MHz EGSM
1800 MHz DCS
1900 MHz TDMA/CDMA/GSM
800 MHz & 1900 MHz CDMA/TDMA
800 MHz CDMA/TDMA & 1900 MHz GSM
900 MHz GSM & 1800 MHz DCS
900 MHz EGSM & 1800 MHz DCS
1800 MHz DCS & 1800 MHz DCS
MTBF (hours) 298,000