User's Manual

PN 8100-40 Help Hot Line (U.S. only): 1-800-530-9960 4-7
620004-0 Rev. B
LGCell Expansion Hub Specifications
4.4 LGCell Expansion Hub Specifications
Note that for dual band systems, the specifications are per band.
Table 4-2 Expansion Hub Specifications
Specification Description
Dimensions (H
× W × D) 44.5 mm × 438 mm × 229 mm (1.75 in. × 17.25 in. × 9 in.); 1U
Weight < 3 kg (< 6.5 lb)
Operating Temperature 0° to 45°C (32° to 113°F)
Operating Humidity, non-condensing 5% to 95%
Clearance Front: minimum 50 mm (2 in.)
Rear: minimum 76 mm (3 in.)
RF Connectors 4 ports, RJ-45
Multimode Fiber Connectors 1 pair, ST female
LED Alarm and Status Indicators UTP/STP Port: Link Status, Sync (4 pair)
Unit Functionality: Sync, Power (1 pair)
AC Power (Universal)
Typical
Maximum
117V AC, 0.47 amp @ 60 Hz
230V AC, 0.24 amp @ 50 Hz
117V AC, 0.64 amp @ 60 Hz
230V AC, 0.32 amp @ 50 Hz
Power Consumption
Typical
Maximum
32 W / 55 W with 4 RAUs
45 W / 75 W with 4 RAUs
Frequencies 800 MHz AMPS/TDMA/CDMA/iDEN
•900 MHz GSM
•900 MHz EGSM
1800 MHz DCS
1900 MHz TDMA/CDMA/GSM
800 MHz & 1900 MHz CDMA/TDMA
800 MHz CDMA/TDMA & 1900 MHz GSM
900 MHz GSM & 1800 MHz DCS
900 MHz EGSM & 1800 MHz DCS
1800 MHz DCS & 1800 MHz DCS
MTBF (hours) 461,000