User Manual

ADCP-75-192 • Issue 1 • December 2005 • Section 2: Description
Page 2-5
2005, ADC Telecommunications, Inc.
Figure 2-4 shows an empty Digital Chassis from the front. Slots on the left are numbered from
1 to 8 starting at the bottom of the chassis. Slots on the right of the chassis are used for the
cPCI power supplies used to power the chassis and modules and the cPCI fan assembly.
Mounting of modules and circuit cards into the Digital Chassis should be done in accordance
with Table 2-3.
Figure 2-4. Digital Chassis - Front
Table 2-3. Digital Chassis Slot Assignments
SLOT MODULE
8 SIF or RSC
7 SIF or RSC
6 SIF or RSC
5 SIF or RSC
4 SIF or RSC
3 SIF or RSC
2 STF2
1 CPU
3 RF CHASSIS
The Hub RF Chassis is a rack-mounted chassis capable of housing 8 industry standard cPCI
circuit card modules. The RF Chassis houses cooling fans and specific modules designed for
use in the Digivance CXD system. The backplane of the RF Chassis provides for distribution
of signals between modules including the reference clock, communications, control and data
signals. Modules used in the RF Chassis include up to two Full-band Hub Down-Converter
(FBHDC) modules, two Forward Simulcast Card (FSC) modules and two Hub Up-Converter
(HUC) modules.
Figure 2-5 shows the empty RF Chassis. The eight empty slots on the left are used for
Digivance CXD modules. The eight empty slots on the right used for housing the cPCI power
supplies which power the modules and the cPCI fan assembly.