The MIB field is:
transceptBtsConnectionTable.transceptBtsConnectionTenantBand
6.2.5 Setting the BIM Rack/Shelf ID
The location information (rack/shelf) of the BIM module belonging to this tenant can be
manually configured. The valid values for these MIB fields are strings of 1-16 characters. The
Hub Config Process will push these ID strings down to the Network Node MIB of the CPU
that controls this BIM. This will allow the NMS to identify the location of the BIM when it is
reporting a fault condition. The MIB fields are:
transceptBtsConnectionTable.transceptBtsConnectionBimRackID
and
transceptBtsConnectionTable.transceptBtsConnectionBimShelfID
6.2.6 Designating the Tenant Hardware
The BTS Connection MIB contains several fields pertaining to the location of the tenant-
specific hardware. Some of the connections made between hardware are not automatically
detectable, and therefore may require some manual entering of information.
The I2C addresses of the RF modules belonging to the tenant being configured can be set (if
changes from default values are required) as follows:
The BIM I2C Address (bus/slot) will automatically be filled in by the Hub Config
Process. The MIB fields are:
transceptBtsConnectionTable.transceptBtsConnectionBimI2cBus
and
transceptBtsConnectionTable.transceptBtsConnectionBimI2cSlot
The BIM module belonging to this tenant must have RF connections to one FBHDC
modules. Select the I2C Bus of the FBHDC module that matches the BIM I2C bus
value. Set the FBHDC I2C slot value to “1”. The FBHDCs belonging to a single tenant
(i.e. having RF connections to the same BIM module) should be co-located in the RF
chassis, with an FSC and HUC modules separating them. The MIB fields are: