User Manual

ADCP-75-192 • Issue 1 • December 2005 • Section 2: Description
Page 2-45
2005, ADC Telecommunications, Inc.
Table 2-28. Digivance CXD Specifications, continued
PARAMETER SPECIFICATION REMARKS
RF connections 50 ohm N-type (female) 50 ohm input/output impedance
Weather resistance NEMA-3R Removable dust filter
Operating temperature –40º to 50º C (-40º to 122º F)
Start-up temperature –20º C (-4º F)
Storage temperature –40º to +85º C (–40 to 185º F)
Humidity 10% to 90%
IP interface RJ-45
AC power ingress ¾-inch conduit Internal diameter
Fiber optical cable ingress ¾-inch conduit Internal diameter
Power input 100 to 260 VAC 47 to 63 Hz
Lightning protection 20 kA IEC 1000-4-5 8/20
microsecond waveform
Battery backup options
Internal – RFA Slot Assembly
External
1 hour
2 hour
Takes one RFA slot
Requires Extended RAN Cabinet
Battery Weight
Internal – RFA Slot Assembly
External
61 lbs.
140 lbs.
Two batteries and tray
Two batteries
Power consumption 600 Watts Two 10 W PA option
Reliability at 25º MTBF 50,000 Excluding fan assemblies
Note 1: Per Industry Canada Section 5.3 - The rated output power of this equipment is for single
carrier operation. For situations where multiple carrier signals are present, the rating would have to
be reduced by 3.5 dB, especially where the output signal is re-radiated and can cause interference to
adjacent band users. The power reduction is to be by means of input power or gain reduction and not
by an attenuator at the output of the device.