User Manual

ADCP-75-158 Preliminary Issue A June 2003 Section 2: Description
Page 2-27
© 2003, ADC Telecommunications, Inc.
The NOC/NEM interface is a command line interface that is presented at an NOC terminal. The
NOC/NEM interface is used for remote control and monitoring operations. The NOC/NEM
interface consists of ASCII text strings that are input as standard SET or GET commands which
are followed by the action or information required. A text string response is received from the
specified system or systems to confirm the requested action or to report the requested
information. Examples of several typical NOC-NEM interface commands and the responses
received are shown in Figure 2-19. The NOC/NEM interface requires only a VT100 terminal/
emulator or a PC-type computer that is loaded with a communication software such as
Procomm Plus. While primarily intended for use at the NOC, the NOC/NEM interface
commands may also be input from the EMS computer.
Figure 2-19. NOC/NEM Interface Typical Commands
11 SPECIFICATIONS
Refer to Table 2-6 for the Digivance 1900 MHz 20 Watt System nominal specifications. All
specifications apply after a five minute warm-up period.
Table 2-6. 1900 MHz 20 Watt System Nominal Specifications
PARAMETER SPECIFICATION REMARKS
Optical - Host and Remote Unit
Fiber type 9/125, single-mode
Number of fibers required
Direct
With WDM
2
1
The wavelength division multi-
plexer (WDM) is an accessory.
Forward path wavelength 1550 nm
Reverse path wavelength 1310 nm
FCC ID: F8I-DLC1902A