3.2 Control and Monitoring Software
The Digivance EMS software supports control and monitoring functions for both the local and
remote service interfaces. The EMS software is stored on a CD-ROM which is included with the
EMS software package. Software installation consists of copying the software files from the
CD-ROM to a designated directory on the hard-drive of the EMS computer.
The EMS software is used to provision and configure the Digivance system for operation. This
includes selecting a sitename, setting alarm thresholds, and setting forward and reverse path RF
gain adjustments. The EMS software is also used to get alarm messages (individual or
summary), data measurements, or to upgrade the HU/RU system software. All control and
monitor functions (except software upgrade which can only be done using the EMS software
GUI) can be effected using either the NOC/NEM interface or the EMS software GUI.
3.3 Fault Detection and Alarm Reporting
LED indicators are provided on the front panel of the HU and on the front panels of the RU
modules to indicate if the system is normal or if a fault is detected. In addition, normally open
and normally closed alarm contacts (for both major and minor alarms) are provided at the HU
for connection to a customer-provided external alarm system. All alarms can also be accessed
through the NOC/NEM interface or the EMS software GUI.
3.4 Powering
The HU is powered by ±24 or ±48 VDC and must be hard-wired to a local office battery power
source through a fuse panel. A screw-down terminal strip is provided on the rear side of the HU
for the power connections.
The RU is powered by 120 or 240 VAC (50 or 60 Hz) and must be connected to an AC power
source through a 20 Amp breaker box. A three-wire cable is provided for the AC power
connections. A 120 VAC outlet should be installed near the RU for powering test equipment or
power tools. In certain applications, it may be necessary to install a surge protector (not
provided) in the AC power feed to prevent equipment damage from AC power spikes.
3.5 Equipment Mounting and Configuration
The HU is designed for mounting in a non-condensing indoor environment such as inside a
wiring closet or within an environmentally-controlled cabinet. The HU is intended for rack-
mount applications and may mounted in either a 19- or 23-inch WECO or EIA equipment rack,
usually within 20 feet of the BTS.
The outdoor RU is designed for mounting in an outdoor environment. The outdoor RU consists
of a Spectrum Transport Module (STM), a Linear Power Amplifier (LPA) module, and a self-
contained cabinet which houses the modular components and protects them from the elements.
The RU cabinet is weather-tight but contact with salt-air mist should be avoided as it may
degrade the MTBF of the product. The outdoor cabinet can be mounted from a flat-vertical
surface, from a utility pole (requires pole-mount kit), or mounted on a pedestal (requires