User's Manual

ADCP-75-158 Issue 1 July 2003 Section 2: Description
Page 2-7
© 2003, ADC Telecommunications, Inc.
3 REMOTE UNIT OUTDOOR CABINET
The RU cabinet, shown in Figure 2-3, is a NEMA-3R enclosure (with removable dust filter) that
provides the following basic functions:
Houses the various electronic modules (STM and LPA) and accessories (WDM or
CWDM) and protects them from the weather.
Provides electrical interface connections for the STM and LPA modules.
Provides ventilation openings to allow for entry of cool air and the escape of heated air.
Provides a point for connecting the antenna cable and ground cable.
Provides entry points for the fiber optic cable and AC power cable.
Provides lightning protection
Provides limited storage for fiber optic pigtails and patch cords.
Provides electrical connections for the CWDM
7 REMOTE UNIT Multi-colored LED
(green/yellow/red)
Indicates if no alarms (green), a minor alarm
(yellow), or a major alarm (red) is reported by the
RU. See Note.
8 DRIVE Multi-colored LED
(green/yellow/red)
Indicates if the level of the RF input signal to the
HU is normal (green), low (yellow), or high
(red). See Note.
9 PORT 1/PORT 2 Multi-colored LED
(green/red)
Indicates if the reverse/forward path optical sig-
nals from the STM/HU are normal (green), if no
optical signals are detected (red), or if excessive
errors are detected (red). See Note.
10 SERVICE DB-9 connector
(female)
Connection point for the RS-232 service inter-
face cable.
11 NET IN RJ-45 jack (female) Connection point for CAN interface input cable.
12 NET OUT RJ-45 jack (female) Connection point for CAN interface output cable.
13 ALARM OUTPUT Screw-type terminal
connector (14–26
AWG)
Connection point for an external alarm system.
Includes normally open (NO), normally closed
(NC), and common (COM) wiring connections.
14 REVERSE 1
RF OUT
N-type female RF
coaxial connector
Output connection point for the primary reverse
path RF coaxial cable.
15 FORWARD
RF IN
N-type female RF
coaxial connector
Input connection point for the forward path RF
coaxial cable.
POWER 24–48 VDC
(Rear side - not shown)
Screw-type terminal
strip
Connection point for the DC power wiring.
Note: A more detailed description of LED operation is provided in Section 5.
Table 2-1. Host Unit User Interface, continued
REF
NO
USER INTERFACE
DESIGNATION
DEVICE
FUNCTIONAL
DESCRIPTION