User Manual

ADCP-75-126 Issue B April 2002 Section 2: Description
Page 2-6
©
2002,
ADC
Telecommunications,
Inc.
3PORT
2SC
connector
(single-mode)
Connection
point
for
the
reverse
path
primary
optical
fiber.
4PORT
3
(diversity
unit
only)
SC
connector
(single-mode)
Connection
point
for
the
reverse
path
diversity
optical
fiber.
5 POWER Multi-colored
LED
(green/yellow)
Indicates
if
the
HU
is
powered
(green)
or
unpow-
ered
(off).
See
Note.
6 STANDBY Multi-colored
LED
(green/yellow/red)
Indicates
if
the
system
is
in
the
Normal
(off),
Standby
(blinking
green),
Test
(blinking
red),
or
Program
Load
(blinking
yellow)
state.
See
Note.
7 HOST
UNIT Multi-colored
LED
(green/yellow/red)
Indicates
if
the
HU
is
normal
(green),
overheated
(yellow),
or
faulty
(red).
See
Note.
8REMOTE
UNIT Multi-colored
LED
(green/yellow/red)
Indicates
if
no
alarms
(green),
a
minor
alarm
(yellow),
or
a
major
alarm
(red)
is
detected
at
the
RU.
See
Note.
9 DRIVE Multi-colored
LED
(green/yellow/red)
Indicates
if
the
level
of
the
RF
input
signal
to
the
HU
is
normal
(green),
low
(yellow),
or
high
(red).
See
Note.
10 PORT
1/PORT
2 Multi-colored
LED
(green/yellow/red)
Indicates
if
the
reverse
path
optical
signal
received
from
the
RU
is
normal
(green),
if
no
sig-
nal
is
detected
(red),
or
if
errors
are
detected
(red).
See
Note.
11 PORT
3
(diversity
unit
only)
Multi-colored
LED
(green/yellow)
Indicates
if
the
diversity
reverse
path
optical
sig-
nal
received
from
the
RU
is
normal
(green),
if
no
signal
is
detected
(yellow),
or
if
errors
are
detected
(yellow).
See
Note.
12 SERVICE DB-9
connector
(female)
Connection
point
for
the
RS-232
service
inter-
face
cable.
13 NET
IN RJ-45
jack
(female) Connection
point
for
the
CAN
interface
input
cable.
14 NET
OUT RJ-45
jack
(female) Connection
point
for
the
CAN
interface
output
cable.
15 ALARM
OUTPUT Screw-type
terminal
connector
(14–26
AWG)
Connection
point
for
an
external
alarm
system.
Includes
normally
open
(NO),
normally
closed
(NC),
and
common
(COM)
wiring
connections.
16 REVERSE
RF
OUT
N-type
female
RF
coaxial
connector
Connection
point
for
the
primary
reverse
path
RF
coaxial
cable.
17 REVERSE
2
RF
OUT
N-type
female
RF
coaxial
connector
Connection
point
for
the
diversity
reverse
path
RF
coaxial
cable.
18 FORWARD
RF
IN N-type
female
RF
coaxial
connector
Connection
point
for
the
forward
path
RF
coaxial
cable.
POWER
24–48
VDC
(Rear
side
-
not
shown)
Screw-type
terminal
strip
Connection
point
for
the
DC
power
wiring.
Note:
A
more
detailed
description
of
LED
operation
is
provided
in
Section
5.
Table 2-1. Host Unit User Interface, continued
REF
NO
USER INTERFACE
DESIGNATION
DEVICE
FUNCTIONAL
DESCRIPTION