User Manual

ADCP-75-126 Issue B April 2002 Section 5: Maintenance
Page 5-7
©
2002,
ADC
Telecommunications,
Inc.
During
normal
HU
operation,
all
LED’s
should
be
green
except
the
STANDBY
LED
which
should
be
Off.
When
a
Minor
alarm
occurs,
one
or
more
of
the
LED’s
will
turn
yellow.
When
a
Major
alarm
occurs,
one
or
more
of
the
LED’s
will
turn
red.
Table 5-6. Remote Unit Minor Alarms
MINOR ALARM LED INDICATOR MINOR ALARM LED INDICATOR
Temperature STM Sec
Laser
Fail STM
Sec
Rev
Mux
Lock STM Sec
Rev
Synth
Lock STM
Rev
Path
Level (Does
not
apply) LPA
Disable SHUTDOWN
(LPA)
LPA
Fan PA LPA
High
Temp PA
Minor
Extern
Alarm
Inp (Does
not
apply) RF
Out
Ve r y
Low (Does
not
apply)
Table 5-7. Host Unit Fault Isolation and Troubleshooting
Alarm Type LED Color
Minor HOST UNIT Yellow
PROBLEM: The HU is overheating.
POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS
1.
Air
intake
or
exhaust
opening
to
HU
chassis
is
blocked
2.
Ambient
temperature
>
50º
C/122º
F.
3.
Faulty
fan.
1.
Remove
cause
of
air-flow
blockage.
2.
Reduce
ambient
temperature.
3.
Replace
HU
fan
(See
Section
5.3).
Alarm Type LED Color
Minor REMOTE UNIT Yellow
PROBLEM: A minor alarm is detected at the RU.
POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS
1.
The
STM
or
LPA
is
overheating.
1.
Check
RU
for
alarms
and
refer
to
Table 5-8
Alarm Type LED Color
Minor DRIVE Yellow
PROBLEM: The RF input signal level is below the underdrive threshold.
POSSIBLE CAUSE CORRECTIVE ACTION/COMMENTS
1.
Faulty
coaxial
connection
between
the
HU
and
the
BTS.
2.
Incorrect
attenuation
in
forward
path
RF
coax-
ial
link.
1.
Check
forward
path
signal
level
at
the
HU.
2.
Check
Host
Forward
Attenuator
setting
and
adjust
if
attenuation
is
too
high.