User Manual

ADCP-75-126 Issue B April 2002 Section 5: Maintenance
Page 5-5
©
2002,
ADC
Telecommunications,
Inc.
Table 5-3. Linear Power Amplifier LED Indicators and Digital Display
INDICATOR COLOR DESCRIPTION
FAIL
Off
Yellow
Indicates
if
the
LPA
is
normal
or
faulty.
The
LPA
is
normal.
Internal
fault
detected
in
the
LPA.
SHUTDOWN
Off
Red
Indicates
if
the
LPA
has
an
RF
output
or
if
the
RF
output
is
shutdown.
The
LPA
RF
output
is
on.
The
LPA
RF
output
is
shutdown.
DISPLAY MESSAGE DESCRIPTION
ADC1940
0
ALARMS
NORMAL
OPERATION
The
LPA
is
normal.
HUNG
CHANG
ADC-1940M
Appears
every
time
power
is
turned
on.
RESTART
AT
STAND
ALONE
MODE
Appears
when
LPA
is
reset.
ADC-1940S Appears
when
an
alarm
has
turned
off
and
the
LPA
is
restart-
ing
after
the
RESET
button
has
been
pressed
or
the
reset
com-
mand
has
been
supplied
from
an
external
source.
PLEASE
WAIT
WHILE
RESTARTING
Appears
while
the
LPA
processor
is
rebooting.
DC
+12V:
+12.0V
DC
+27V:
+27.0V
DC
+32V:
+32.0V
DC
-12V:
-12.0V
Alternately
displays
the
voltage
flow
in
each
part
of
the
LPA.
TEMPER
100.0
ºC Indicates
the
current
temperature
of
the
LPA
heat
sink.
OVER
POWER
ALARM Output
power
has
exceeded
100
W.
HIGH
TEMPERATURE Alarm:
Temperature
of
LPA
exceeds
85
ºC.
VSWR
ALARM Reflected
LPA
power
exceeds
20
W.
LOOP
FAIL General
fault
occurred
in
the
LPA
loops.
FANFAIL One
or
more
fans
have
failed.
FORCED
SHUTDOWN The
RF
ON/OFF
switch
is
in
the
OFF
position
or
the
LPA
was
set
in
the
disable
mode
through
the
EMS
computer.
Alternating
FORCED
SHUTDOWN
and
alarm
message
An
alarm
has
remained
for
over
5
seconds.
DC
FAIL
+12V
-12V
+32V
Volt a g e
is
outside
the
preset
ranges:
+11
to
+13V
-13
to
-11V
+30