ADCP-75-112 • Issue 2A • June 2001 ™ Digivance Indoor Coverage Solution 800/1900 MHz Digital Remote Unit Installation Instructions Content Page INTRODUCTION............................................................................2 1 2 3 DESCRIPTION........................................................................3 1.1 Digital Remote Unit ..............................................................3 1.2 Antenna Options ................................................................5 1.
ADCP-75-112 • Issue 2A • June 2001 INTRODUCTION This publication provides instructions for installing the Digivance Indoor Coverage Solution (ICS) Digital Remote Unit (DRU). A more complete description of the DRU along with the operating and maintenance procedures is provided in the Digivance ICS Installation and Operation Manual (ADCP-75-110). The DRU is installed in conjunction with the Digital Host Unit (DHU) and the Digital Expansion Unit (DEU).
ADCP-75-112 • Issue 2A • June 2001 1 DESCRIPTION This section describes the DRU, the various DRU antennas, and the AC/DC power converter (optional accessory item). 1.1 Digital Remote Unit The DRU, shown in Figure 1, serves as the cellular user servicing unit for the Digivance ICS. The DRU consists of an electronic circuit board assembly that is mounted within a powdercoated sheet metal enclosure. The electronic circuit board assembly is not user replaceable.
ADCP-75-112 • Issue 2A • June 2001 The DRU is equipped with a female RJ-45 jack that provides a point for connecting a DC power cable. The DRU is powered by 34–48 Vdc power which is supplied through the RJ-45 connector. Power to the DRU may be supplied by the DHU, DEU, or by a 120 Vac to 48 Vdc power converter (available separately as an accessory item) plugged into a properly grounded 120 Vac outlet.
ADCP-75-112 • Issue 2A • June 2001 1.2 Antenna Options Various antennas, shown in Figures 3 and 4, are available from ADC for use with the DRU. All antennas include a 6 foot (1.8 m) long 50-ohm coaxial cable (equipped with SMA male connector) for connection to the DRU. The DRU is equipped with an SMA female connector for connecting the antenna cable.
ADCP-75-112 • Issue 2A • June 2001 ALL ANTENNAS ARE EQUIPPED WITH A 72-INCH RG58/U CABLE TERMINATED WITH A MALE SMA CONNECTOR MOUNTING STUD LENGTH - 1.5 INCHES (38 mm) DIAMETER - 0.875 INCHES (22 MM) DIAMETER - 4.25 INCH (105 MM) DEPTH - 0.57 INCH (14 MM) 2.5 INCHES (64 MM) 4 dBi GAIN CEILING-MOUNT HALLWAY 2.5 dBi GAIN CEILING-MOUNT OMNIDIRECTIONAL 3 INCHES (76 MM) 5 INCHES (127 MM) 0.5 INCHES (13 MM) MOUNTING BASE NOT SHOWN 4.6 INCHES (118 MM) 7.5 dBi GAIN DIRECTIONAL PANEL (WALL-MOUNT) 1.
ADCP-75-112 • Issue 2A • June 2001 15988-A Figure 5. AC/DC Power Converter 2 INSTALLATION PROCEDURE This section provides the installation procedures for the DRU, the antennas, and the AC/DC power converter (if used). Installation of the DRU may proceed separately from the installation of the DHU and the DEU. When the installation of the DRU is completed, refer to the Digivance ICS Installation and Operation Manual (ADCP-75-110) for the system turn-up and test procedures. 2.
ADCP-75-112 • Issue 2A • June 2001 2.2 Unpacking and Inspection This subsection provides instructions for opening the shipping boxes, verifying that all parts have been received, and verifying that no shipping damage has occurred. Use the following procedure to unpack and inspect the DRU: 1. Open the shipping carton and carefully unpack the DRU from the protective packing material. 2. Check the DRU for broken or missing parts.
ADCP-75-112 • Issue 2A • June 2001 2.4 DRU Mounting Procedure The DRU may be mounted on any flat vertical or horizontal surface. A slot is provided in each of the four mounting feet for inserting a fastener. The fasteners must be provided by the installer. Use the following procedure to mount the DRU: Warning: Wet conditions increase the potential for receiving an electrical shock when installing or using electrically-powered equipment.
ADCP-75-112 • Issue 2A • June 2001 NOTE: THE DRU FRONT PANEL MAY ALSO BE ORIENTED DOWNWARD FOR VERTICAL MOUNT 16450-A HORIZONTAL MOUNT VERTICAL MOUNT Figure 5. DRU Mounting 2.5 Antenna Mounting Procedure Various types of antennas are available from ADC for use with the DRU. All antennas include a 6-foot (1.8 m) long 50-ohm coaxial cable for connection to the DRU. Each type of antenna provides a specific coverage pattern in order to accommodate the shape of the area where coverage is required.
ADCP-75-112 • Issue 2A • June 2001 SMA CONNECTOR 7/8-14 NYLON HEX JAM NUT I-INCH (25 mm) DIAMETER HOLE CEILING TILE NOTE: TO COMPLY WITH MAXIMUM PERMISSIBLE EXPOSURE (MPE) REQUIREMENTS, ANTENNAS MUST BE INSTALLED TO PROVIDE AT LEAST 20 CENTIMETERS OF SEPARATION FROM ALL PERSONS PER FCC 47 CFR PART 2.1091. THREADED SPACER (REMOVE IF NOT NEEDED) 16244-A Figure 8. 800 and 1900 MHz Ceiling-Mount Omnidirectional Antenna Installation 2.5.
ADCP-75-112 • Issue 2A • June 2001 SMA CONNECTOR 7/8-14 NYLON HEX JAM NUT I-INCH (25 mm) DIAMETER HOLE CEILING TILE NOTE: TO COMPLY WITH MAXIMUM PERMISSIBLE EXPOSURE (MPE) REQUIREMENTS, ANTENNAS MUST BE INSTALLED TO PROVIDE AT LEAST 20 CENTIMETERS OF SEPARATION FROM ALL PERSONS PER FCC 47 CFR PART 2.1091. THREADED SPACER (REMOVE IF NOT NEEDED) 16245-A ORIENT ANTENNA SO FLAT SIDES ARE PERPENDICULAR WITH HALLWAY WALLS Figure 9. 800 MHz Ceiling-Mount Hallway Antenna Installation 2.5.
ADCP-75-112 • Issue 2A • June 2001 5. Hold the antenna in position for mounting on the hard ceiling. 6. Mark the location of the two antenna bracket mounting holes on the hard ceiling. 7. Drill a 1/8-inch (3 mm) hole at each of the two locations marked in step 6. 8. Secure the antenna mounting bracket to the hard ceiling using two #4 screws (must be provided by installer). 9. Route antenna cable to DRU.
ADCP-75-112 • Issue 2A • June 2001 DRILL HOLES THROUGH PLASTIC COVER ONLY. SEE REAR SIDE FOR HOLE LOCATIONS. NOTE: TO COMPLY WITH MAXIMUM PERMISSIBLE EXPOSURE (MPE) REQUIREMENTS, ANTENNAS MUST BE INSTALLED TO PROVIDE AT LEAST 20 CENTIMETERS OF SEPARATION FROM ALL PERSONS PER FCC 47 CFR PART 2.1091. MAKE SURE ARROW ON REAR SIDE OF ANTENNA IS POINTING UP WHEN ANTENNA IS MOUNTED 5/8-INCH (16 mm) HOLE FOR ANTENNA CABLE USE APPROPRIATE FASTENERS FOR WALL SURFACE 16246-A Figure 11.
ADCP-75-112 • Issue 2A • June 2001 DRILL HOLES THROUGH PLASTIC COVER ONLY. SEE REAR SIDE FOR HOLE LOCATIONS. NOTE: TO COMPLY WITH MAXIMUM PERMISSIBLE EXPOSURE (MPE) REQUIREMENTS, ANTENNAS MUST BE INSTALLED TO PROVIDE AT LEAST 20 CENTIMETERS OF SEPARATION FROM ALL PERSONS PER FCC 47 CFR PART 2.1091.
ADCP-75-112 • Issue 2A • June 2001 NOTE: TO COMPLY WITH MAXIMUM PERMISSIBLE EXPOSURE (MPE) REQUIREMENTS, ANTENNAS MUST BE INSTALLED TO PROVIDE AT LEAST 20 CENTIMETERS OF SEPARATION FROM ALL PERSONS PER FCC 47 CFR PART 2.1091. ORIENT TO CENTER OF COVERAGE AREA BASE ASSEMBLY 5/8-INCH (16 mm) HOLE FOR ANTENNA CABLE HANDLE MAKE SURE ARROW ON REAR SIDE OF ANTENNA IS POINTING UP WHEN ANTENNA IS MOUNTED 16247-A Figure 13. 800 MHz 90º Panel Antenna Installation 2.
ADCP-75-112 • Issue 2A • June 2001 ANTENNA PORT SMA CONNECTOR 16451-A TORQUE WRENCH SET TO 5 INCH-POUNDS (45 N.CM) Figure 14. DRU Antenna Connection 2.7 Optical Connection The optical interface between the DRU and the DHU or DEU is supported by a small form factor LC-type optical transceiver which is mounted on the DRU front panel. One side of the transceiver provides the optical fiber connection for the forward path (downlink) signal.
ADCP-75-112 • Issue 2A • June 2001 OPTICAL CONNECTOR ASSEMBLY DETAIL REVERSE PATH (TX) CONNECTOR FORWARD PATH (RX) CONNECTOR 16452-A OPTICAL ADAPTER OPTICAL CONNECTOR Figure 15. Optical Port Fiber Optic Cable Connection 4. Remove the dust caps from the optical fiber connectors and from the DRU optical port. 5. Clean each connector (follow connector supplier’s recommendations) and then insert the optical link connector pair into optical port as shown in Figure 15. 6.
ADCP-75-112 • Issue 2A • June 2001 16453-A 1 8 POWER PORT POWER CONNECTOR Figure 16. DC Power Cable Connection 3. Dress and secure the power cable at the DRU per standard industry practice. 4. When the installation of the DRU is completed, refer to Section 4 of the Digivance ICS Installation and Operation Manual (ADCP-75-110) for the system turn-up and test procedures. 2.8.
ADCP-75-112 • Issue 2A • June 2001 2. Connect the DC power cable to the 48 Vdc connector on the DRU (see Figure 16). 3. Locate the AC power cord which is provided with the AC/DC power converter. Use only the AC power cord provided with the power converter or an equivalent UL/CUL listed and certified 3-conductor, 18 AWG cord terminated in a molded-on plug cap rated 125 V, 15 A with a maximum length of 6 feet (1.8 m).
ADCP-75-112 • Issue 2A • June 2001 3 CUSTOMER INFORMATION AND ASSISTANCE For customers wanting information on ADC products or help in using them, ADC offers the services listed below. To obtain any of these services by telephone, first dial the central ADC telephone number, then dial the extension provided below. The central number for calls originating in the U.S.A. or Canada is 1-800-366-3891. For calls originating outside the U.S.A. or Canada, dial country code “1” then dial 952-946-3000.