® ADC FlexWave Prism Element Management System 7.
Copyright © 2011 ADC Telecommunications, Inc. All Rights Reserved. Information contained in this document is company private to ADC Telecommunications, Inc. and shall not be modified, used, copied, reproduced or disclosed in whole or in part without the written consent of ADC. Trademark Information ADC and FlexWave are registered trademarks, and InterReach Spectrum and Universal Radio Head are trademarks of ADC Telecommunications, Inc.
TABLE OF CONTENTS Preface __________________________________________________________ix FlexWave Prism User Documentation ......................................................................................... x EMS Document Overview .........................................................................................................xi Document Cautions and Notes.............................................................................................xi Document Fonts ...............................
Table of Contents Part II: System Setup ______________________________________ 37 Using the Prism EMS_______________________________________________ 39 How to Use the EMS Graphical User Interface ............................................................................40 System Tree ....................................................................................................................41 System Tree Icons........................................................................................
Table of Contents Part III: System Management ________________________________ 97 System Information _______________________________________________ 99 Get Information ................................................................................................................... 100 Accessing System Reports ............................................................................................... 101 Viewing the Software/Firmware Report .............................................................
Table of Contents Alarms ________________________________________________________ 167 View Current Alarms............................................................................................................. 168 Clear Current Alarms ............................................................................................................ 170 View Alarm History............................................................................................................... 170 Clearing Alarm History .
Table of Contents Using an SNMP Interface __________________________________________ 229 SNMP Overview ................................................................................................................... 230 Working with Prism MIB Files................................................................................................. 231 Accessing Prism MIBs......................................................................................................
Table of Contents Intentionally Blank Page Page viii © 2011 ADC Telecommunications, Inc FlexWave Prism Element Management System 7.
PREFACE Topics Page FlexWave Prism User Documentation ......................................................................................... x EMS Document Overview .........................................................................................................xi Document Cautions and Notes.............................................................................................xi Document Fonts ................................................................................................
FlexWave Prism User Documentation F LEX W AVE P RISM U SER D OCUMENTATION FlexWave Prism documentation is intended for system administrators, engineers and installers responsible for planning, administering, configuring, and maintaining FlexWave Prism systems. The following table lists the manuals that correspond to this FlexWave Prism release.
Preface Document Fonts You will find the following font conventions in use throughout the document. • This font represents a reference to a EMS dialog box, menu item, configuration option, or other parameter. • in angle brackets represents a reference to a EMS dialog box, menu item, configuration option, or other parameter that is a variable. The text within the angle brackets changes according to a get or set command.
FlexWave Prism User Documentation Document Graphics This manual documents an EMS, the features of which display in a web browser window, as described in “How to Use the EMS Graphical User Interface” on page 40. To display the entire web browser would reduce the image size in this document, which would reduce the document’s usability. The screen graphics will therefore focus on the element of the web page under discussion.
Preface ABBREVIATIONS/ACRONYMS This section defines abbreviations/acronyms used in this manual.
Abbreviations/Acronyms Abbreviations/Acronyms Definition SNMP Simple Network Management Protocol TX Transmit UPS Uninterruptible Power Supply URU URH Remote Unit VLAN Virtual Local Area Network VSWR Voltage Standing Wave Ratio WDM Wavelength Division Multiplexer Page xiv © 2011 ADC Telecommunications, Inc FlexWave Prism Element Management System 7.
PART I FLEXWAVE PRISM HARDWARE FlexWave Prism Element Management System 7.1 User Manual ADCP-77-177 • Issue 1 • July 2011 Page 1 © 2011 ADC Telecommunications, Inc.
Intentionally Blank Page Page 2 © 2011 ADC Telecommunications, Inc FlexWave Prism Element Management System 7.
PRISM SYSTEM OVERVIEW Topics Page Prism System Overview ........................................................................................................... 4 Fiber Optic Transport..............................................................................................................10 Host Unit Overview ................................................................................................................11 Fan Module..................................................................
Prism System Overview P RISM S YSTEM O VERVIEW ADC’s FlexWave® Prism is a compact radio head utilized for precision and macro gap coverage, which supports up to four frequency bands, while delivering high-performance coverage with end-to-end management. FlexWave Prism is ideal for enhancing outdoor and indoor coverage in urban, suburban, canyons, tunnels, campuses, stadiums and other public venues.
Prism System Overview Examples of FlexWave Prism Systems are shown in Figure 1, Figure 2 on page 6, and Figure 3 on page 7. Host Unit Antenna Frequency Band A Antenna Frequency Band B RF Antenna Frequency Band C RF RF Frequency Band A Frequency Band B Frequency Band C Tri-Band Remote Unit Base Transceiver Stations Figure 1. Three Bands to One PRU (No Simulcast) FlexWave Prism Element Management System 7.1 User Manual ADCP-77-177 • Issue 1 • July 2011 Page 5 © 2011 ADC Telecommunications, Inc.
Prism System Overview Antenna Frequency Band A Sector A Antenna Frequency Band A Sector B Host Unit RF RF RF Frequency Band A Sector A Frequency Band A Sector B Antenna Frequency Band A Sector G Frequency Band A Sector G Base Transceiver Stations Three Single-Band Remotes Figure 2. Multiple Point-to-Point Configuration (One Band per PRU, Three Nodes) Page 6 © 2011 ADC Telecommunications, Inc FlexWave Prism Element Management System 7.
Prism System Overview Four Tri-Band Remotes Antenna Frequency Band A Antenna Frequency Band A Antenna Frequency Band B Antenna Frequency Band B Antenna Frequency Band C Antenna Frequency Band C Antenna Frequency Band A Antenna Frequency Band A Antenna Frequency Band B Antenna Frequency Band B Antenna Frequency Band C Antenna Frequency Band C Host Unit RF RF RF Frequency Band A Base Transceiver Stations Frequency Band B Frequency Band C Figure 3.
Prism System Overview A block diagram of a point-to-point system is shown in Figure 4.
Prism System Overview The basic function of FlexWave Prism simulcast (point-to-multipoint) is to transport, via fiber optic cable, RF signals from a BTS to multiple antenna interfaces allowing communication to a mobile device (see Figure 5). Up to 8 simulcast Remote Units are supported by each Host Unit.
Fiber Optic Transport FIBER OPTIC TRANSPORT In a FlexWave Prism system, each BTS provides the RF channel inputs and outputs for a designated sector. Each Host may be interfaced with one or more Base Transceiver Station (BTS). On the forward path, the Host receives Analog RF signals from the BTS, digitizes the designated RF bands, and then transports them over single-mode fiber to up to 8 Remote Units.
Prism System Overview H OST U NIT O VERVIEW The rack-mountable Host is typically located with the RF source—a Base Transceiver Station (BTS). The Host is DC powered and supports up to eight BTS interfaces through DART (Digital/Analog Radio Transceiver) cards. (For further information on DART Modules, see “DART Modules” on page 24.
Host Unit Overview SeRF II Module The SeRF II Module: • manages communications and alarms • receives digitized signals from the DART and sends the digitized RF bands to the designated PRU • receives digitized RF signals from the PRU and sends the digitized RF signal to the DART for conversion from Digital RF to Analog RF for the BTS/BDA • supports eight Small Form-factor Pluggable (SFP) optical transceivers • provides two Ethernet interfaces.
Prism System Overview SeRF II Module LEDs SFP8 Tx Rx Rx Tx LEDs for SFP in top port 1 LEDs for SFP in bottom port SFP7 2 3 4 5 Ref # LED SFP TX LED Color 4 • • • SFP RX • • • • • ALARM • • SYNTH • • STATUS • 5 POWER 1 2 3 OFF GREEN RED OFF GREEN AMBER RED GREEN RED GREEN RED GREEN RED • GREEN • RED • OFF Description • • • • • • • • • • • • • No Small Form-Factor Pluggable (SFP) present SFP is present and the FPGA internal Phase-Locked Loop (PLL) is locked SFP is present and the FPGA inte
Host Unit Overview Host System II Module The Host System II Module: • provides output dry alarm contacts for reporting alarms to an external management system • can output the reference clock to a daisy-chained Host. Host System II Module Ports and Connectors 1 2 3 4 5 6 Ref # Component Device Function 1 REF IN connector QMA-Type female RF coaxial connector 10 MHz reference clock input that may be used to synchronize between multiple Hosts in a daisy-chain configuration.
Prism System Overview Host System II Module LEDs 1 2 4 3 Ref # LED 1 LED Color Description • Green • An external reference has been selected in the Prism Element Management System GUI. Once this selection has been made in the GUI, the REF IN LED is green, regardless of the presence of a signal on the REF IN connector. • No external reference has been selected in the Prism Element Management System GUI. For this release, this LED will always be off in a Prism Host Unit. REF IN • Off 2 30.
Prism Remote Units PRISM REMOTE UNITS The Prism Remote Unit (PRU), shown in Figure 8, controls RF emissions, interfaces with the FlexWave Host and performs the optical to electrical conversions for transport to the antennas. The PRU is an IP-65 rated enclosure that houses the electronic assemblies such as the RF Module Group, SeRF assembly and AC/DC power supplies, and seals out dirt and moisture. The PRU uses fans located on the top of each unit to cool the chassis.
Prism System Overview PRU Ports and Connectors (Bottom of PRU) 2 1 NETWORK 6 AUX. MOD A RX1 MOD A TX0/RX0 FIBER 1 MOD D TX0/RX0 MOD D RX1 MOD C TX0/RX0 MOD C RX1 MOD B RX1 MOD B TX0/RX0 3 FIBER 2 5 POWER 100-240 VAC 50-60 Hz 16 AMPS 4 Bottom of a PRU Ref # Component Device Function 1 Aux Connector Four contact closure inputs Connection points for external alarm inputs.
Prism Remote Units PRU Status LED (Bottom of PRU) NETWORK AUX. MOD A RX1 MOD A TX0/RX0 FIBER 1 MOD D TX0/RX0 Staus LED MOD D RX1 MOD C TX0/RX0 MOD C RX1 MOD B RX1 MOD B TX0/RX0 FIBER 2 POWER 100-240 VAC 50-60 Hz 16 AMPS Status LED—Bottom of a PRU The PRU has a single red Status LED that is located on the bottom of the chassis. At system startup, the PRU Status LED is red to indicate that the PRU is powering up and that the SeRF processor does not yet control the PRU.
Prism System Overview PRU Components The PRU chassis is an outdoor-rated enclosure that comprises the following components: • Power Supplies • SeRF Module • Fans • Interface connections as described in “PRU Ports and Connectors (Bottom of PRU)” on page 17 • External Status LED (see “PRU Status LED (Bottom of PRU)” on page 18) • Remote (AC) power and RF Module (DC) power switches PRUs ship with specified RF Modules pre-installed.
Prism Remote Units Figure 9 shows components within the Remote Unit chassis. RF Module (one of four in this Quad-Band Prism) Duplexer Linear Power Amplifier Remote DART Interface (RDI) (one on each RF Module) DART card (one or two on each RF Module) DC Power switches for RF Modules SeRF Module AC Power switch Cable connectors and Status LED 77072-009 Figure 9. Prism Remote Unit (PRU) Components Page 20 © 2011 ADC Telecommunications, Inc FlexWave Prism Element Management System 7.
Prism System Overview RF Module Capabilities and GUI Representation A PRU comprises from one to four RF Module slots. Each RF Module can comprise any of the following DART combinations: • one Classic DART or one Single SuperDART • two Classic DARTs • two Single SuperDARTs • one Dual SuperDART. A PRU can therefore comprise up to eight single-slot DARTS or up to four Dual SuperDARTs, dependent on the Remote chassis size and the number of RF Modules installed.
Prism Remote Units Table 1 and Figure 10 on page 23 describe how the EMS references the RF group assignments and corresponding components of each RF Module. Table 1.
Prism System Overview DART 7 Group D DART 8 DART 5 Group C DART 6 DART 3 Group B DART 4 DART 1 Group A DART 2 SeRF Module 77152-010 Figure 10. DART RF Groups in a Prism Remote Unit FlexWave Prism Element Management System 7.1 User Manual ADCP-77-177 • Issue 1 • July 2011 Page 23 © 2011 ADC Telecommunications, Inc.
DART Modules DART MODULES DART Modules: • amplify, down-convert, filter and digitize the incoming RF signal • convert incoming digital signal from the SeRF to analog, filter, amplify and up-convert the frequency from Intermediate Frequency (IF) to RF • provide a bi-directional interface between RF and the SeRF board (via FPGA, D/A converter, and A/D converter) • provide uplink gain • support Simplex RF interfacing to/from the BTS • perform adjustable delay processing.
Prism System Overview Table 3.
DART Modules Host DARTs The Host can support up to eight Classic DARTS and/or Single SuperDARTs or up to four Dual SuperDARTs. Figure 11 provides generic representations of Classic DARTS or Single SuperDARTs and Dual SuperDARTs. Generic representation of a Classic DART or Single SuperDART Generic representation of a Dual SuperDART 77073-076 Figure 11. DART Modules Figure 12 shows a Host that is fully loaded with Dual SuperDART Modules.
Prism System Overview Host DART Slots Figure 13 shows the possible slot assignments for Single and Dual SuperDARTs, and where slot-divider bars are located.
DART Modules Host DART Connectors and LEDs Only RF DART Modules can be installed in the Host Unit.
Prism System Overview Serialized RF (SeRF) Digital Protocol The SeRF (Serialized RF) digital protocol consists of digitized RF, Fast Ethernet, and Host to Remote communication and management. The protocol provides you with full access to the 100BASE-T (Ethernet) connection between the Host and each Remote, and the ability to provision the RF spectrum of the DARTs.
DART Modules Simulcast Groups Simulcast combining occurs when more than one Remote DART is linked to the same Host DART. The gains of the reverse signals are reduced before summation to prevent over-flow when the digital signals are added together. This simulcast gain reduction is accomplished as a function of the number of Remote DARTs linked to the Host DART (N) and the selected Reverse Gain Mode: • Mode 1 (Noise Floor Matching)—uses an algorithm that normalizes the noise floor of all Remote Units.
Prism System Overview Use of Multi Fibers The EMS provides the ability to install “multi fibers” between a Host and Remote. This means that, in addition to the minimum single fiber pair (RX and TX) in the Host to Remote connection, one or more additional fiber pairs are installed. This is done to increase the bandwidth or number of timeslots between the Host and Remote.
DART Modules E911 Support The DART type determines the maximum number of links, where there can be up up to 8 Classic DARTs or Single SuperDARTs that support 35MHz each, or up to 4 Dual SuperDARTs that support up to 75MHz each. E911 support may be achieved by using a configuration similar to the one shown in Figure 14. Remote simulcasting in this configuration requires analog splitting and combining to and from the individual Host DARTs.
Prism System Overview PRISM SYSTEM SPECIFICATIONS Table 7. Parameter RF and Optical Specifications Specification a Remarks RF Specifications Supported Frequency Blocks 1-8 per Host Unit Bandwidth 1.
Prism System Specifications Table 7. RF and Optical Specifications (Cont.) Parameter Specification a Remarks Optical - Host II and Remote Units Fiber type 9/125, single-mode up to 75 MHz RF per fiber pair (or fiber if using WDM). Number of fibers required Assumes RF bandwidth does not exceed 3 Gbps data rate capacity of the fiber. Optical - WDM WDM Passband 1310 nm ± 20 nm 1550 nm ± 20 nm Forward path insertion loss Host WDM 0.7 dB Remote WDM 0.
Prism System Overview Table 9. Remote Unit Technical Specifications Parameter Specification Remarks Enclosure dimensions Height x Width x Depth Single-Band Inches 25.2 Centimeters 64 x 12.2 30.99 x 11.2 28.45 • Dimension for width includes the mounting brackets. Dual-Band Inches 33.2 Centimeters 84.3 x 12.2 30.99 x 11.2 28.45 Tri-Band Inches 41.2 Centimeters 104.6 x 12.2 30.99 x 11.2 28.
Prism System Specifications Intentionally Blank Page Page 36 © 2011 ADC Telecommunications, Inc FlexWave Prism Element Management System 7.
PART II SYSTEM SETUP FlexWave Prism Element Management System 7.1 User Manual ADCP-77-177 • Issue 1 • July 2011 Page 37 © 2011 ADC Telecommunications, Inc.
Intentionally Blank Page Page 38 © 2011 ADC Telecommunications, Inc FlexWave Prism Element Management System 7.
USING THE PRISM EMS Topics Page How to Use the EMS Graphical User Interface ............................................................................40 System Tree ....................................................................................................................41 System Tree Icons............................................................................................................42 EMS View Frame Elements.........................................................................
How to Use the EMS Graphical User Interface H OW TO U SE THE EMS G RAPHICAL U SER I NTERFACE You use a web browser to access the EMS Graphical User Interface (GUI) shown in Figure 15 and described in Table 10. 8 7 1 2 3 4 5 6 Figure 15. EMS Graphical User Interface Page 40 © 2011 ADC Telecommunications, Inc FlexWave Prism Element Management System 7.
Using the Prism EMS Table 10. GUI Components ID # Component Description 1 System Menu bar Provides access to menus that allow you to configure or view system settings and alarms. 2 System Tree See “System Tree” on page 41. 3 Alarm indicators Provides a visual view of the number of active alarms and their severity level. Execute the command for which the button is labeled: 4 Operational buttons • Apply—Applies your configuration changes without closing the dialog.
How to Use the EMS Graphical User Interface System Tree Icons Table 11 describes the icons used in the System Tree. Table 11. System Tree Icons Icon Unit/State Description Host Host Unit; normal status PRU Prism Remote Unit; normal status URU Universal Radio Head Remote Unit; normal status Minor Alarm State A yellow caution overlay on a unit icon indicates that the unit has an active Minor alarm. If the icon is blinking, the alarm is unacknowledged.
Using the Prism EMS Table 12. View Frame Elements ID # Element Description 1 A panel is a grouping of fields or parameters enclosed within a grey box, with the panel title in the upper-left corner. Panel A square box is a selection box that you click on to select or deselect an option. When selected, a checkmark displays in the box. When the option is deselected, the box is empty. 2 Selection box/Radio button 3 List A menu that lists the options for the corresponding parameter.
How to Use the EMS Graphical User Interface Viewing Parameters and Alarms You can view any parameter or alarm by navigating to the page in which the parameter or alarm resides. To quickly find information about a parameter or alarm: • All parameters are listed alphabetically in this manual’s Index. • All alarms are listed alphabetically in this manual’s Index of Alarms. • All traps are listed alphabetically in this manual’s Index of Traps.