ADC In-Building 850 and 1900MHz Wireless Repeater User Manual ADCP-75-237 • Issue 1 • 8/2007 1xxxxxx Rev A
ADC In-Building 850 and 1900MHz Wireless Repeater User Manual ADCP-75-237 • Issue 1 • 8/2007 1xxxxxx Rev A
ADCP-75-237 • Issue 1 • 8/2007 • Preface COPYRIGHT © 2007, ADC Telecommunications, Inc. All Rights Reserved REVISION HISTORY ISSUE DATE 1 08/2007 REASON FOR CHANGE Original LIST OF CHANGES The technical changes incorporated into this issue are listed below. PAGE IDENTIFIER All DESCRIPTION OF CHANGE New publication TRADEMARK INFORMATION ADC and Digivance are registered trademarks of ADC Telecommunications, Inc. DISCLAIMER OF LIABILITY Contents herein are current as of the date of publication.
ADCP-75-237 • Issue 1 • 6/2007 • Preface TABLE OF CONTENTS Content Page ABOUT THIS MANUAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii ADMONISHMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii GENERAL SAFETY PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ADCP-75-237 • Issue 1 • 6/2007 • Preface TABLE OF CONTENTS Content Page 4.1 Fwd Base Volt. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-10 4.2 Rev Base Volt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-11 4.3 Band Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ADCP-75-237 • Issue 1 • 8/2007 • Preface ABOUT THIS MANUAL This manual describes the installation and operation of the ADC In-Building Wireless Repeater. The repeater is normally mounting inside and distributes the RF over coax to an indoor antenna located in the desired coverage area. ADMONISHMENTS Important safety admonishments are used throughout this manual to warn of possible hazards to persons or equipment.
ADCP-75-237 • Issue 1 • 8/2007 • Preface Caution: Always allow sufficient fiber length to permit routing of patch cords and pigtails without severe bends. Fiber optic patch cords or pigtails may be permanently damaged if bent or curved to a radius of less than 2 inches (5.1 cm). Caution: Exterior surfaces of the RAN may be hot. Use caution during servicing.
ADCP-75-237 • Issue 1 • 8/2007 • Preface Warning: This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual, may cause interference to radio communications. It has been tested and found to comply with limits for a Class B digital device pursuant to Subpart A of Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference when operated in a residential environment.
ADCP-75-237 • Issue 1 • 8/2007 • Preface radio communications. Changes and modifications not expressly approved by the manufacturer or registrant of this equipment can void your authority to operate this equipment under Federal Communications Commissions rules. In order to maintain compliance with FCC regulations, shielded cables must be used with this equipment. Operation with non-approved equipment or unshielded cables is likely to result in interference to radio & television reception.
ADCP-75-237 • Issue 1 • 8/2007 • Preface FDA FCC GPS IC IN IP KG LED LSE LVD MHz MTBF MUX Node NXD OSP PA PAA PC PCI PIC P/MCPLR RAN RDC RDC2 RF RUC RUC2.X RUC3 SFP SIF SNMP SONET STF2 UL VAC VDC VSWR WDM WSP U.S. Food and Drug Administration U.S.
ADCP-75-237 • Issue 1 • 8/2007 • Preface Page xii © 2007, ADC Telecommunications, Inc.
ADCP-75-237 • Issue 1 • 8/2007 • Section 1: OVERVIEW SECTION 1: OVERVIEW Content 1 Page DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1 1.1 1.2 2 RF SIGNAL FLOW (850MHz) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1 1.1.1 Forward (Down) Link . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ADCP-75-237 • Issue 1 • 8/2007 • Section 1: OVERVIEW 1.1.2 Reverse(Up) Link The reverse link and the forward link have a same structure. Frequency raging from 824 ~ 849MHz received by the service antenna go into the duplexer. The duplexer removes all unwanted signals and sends the specific signal to the LNA. The reverse link signal received by the LAN is amplified by the drive amplifier and Down Mixer where IF signal conversion is done.
ADCP-75-237 • Issue 1 • 8/2007 • Section 1: OVERVIEW 2 FEATURES 2.1 LED Status Five LEDs on the front display repeaters status. LED indicators are defined in Table 1-1. Table 1-1.LED Indicators 2.2 COLOR STATUS Red Tx Shut Down Red Rx Shut Down Yellow Sleep Mode Red Isolation Check Green DC Power Automatic Level Control (ALC) If the forward or reverse RF output power exceeds 13dBm, the system automatically controls the output power to maintain power and protect the repeater. 2.
ADCP-75-237 • Issue 1 • 8/2007 • Section 1: OVERVIEW 2.6.1 850MHZ Repeater Band Selection Band Selection is available within the US CELLULAR 25MHz bandwidth. User can select either A band set (A”+A +A’) or B band set (B + B’) for 12.5MHz Bandwidth each, totaling 25MHz, or request the manufacturer to set the bandwidth before shipping the product from the factory. Band selection is shown in Table 1-2. Table 1-2.Band Selection Table (850MHz) FREQUENCY (MHZ) BAND 2.6.
ADCP-75-237 • Issue 1 • 8/2007 • Section 2: Installation SECTION 2: INSTALLATION Content 1 Page REPEATER INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-1 1.1 1.2 Mechanical Attachment of Repeater. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-1 1.1.1 Standard Wall Mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ADCP-75-237 • Issue 1 • 8/2007 • Section 2: Installation Figure 2. Example of PDU Standard Wall Mount 1.2 Installation of Repeater Cables There are four connection points on the repeater; two antenna connectors, one power connector, and one USB port. A USB cable is required when configuring the repeater using the GUI. Plug one end of the USB cable into the port on the bottom of the repeater and plug the other end into a USB port connected to the PC. Power Connection Donor Antenna Indoor Antenna 1.
ADCP-75-237 • Issue 1 • 8/2007 • Section 2: Installation 2. Connect the alarm cable leads to the base station or site alarm system. Use either “Normally Open” or “Normally Closed” contacts. shows the PDU alarm logic 3. Connect the other end of the alarm cable to the PDU “ALARM” connector. 4. Connect the power cable to the site DC power connector. (The power cable has three leads. Red is positive, Black is negative, and Yellow/Green is for ground.) 5.
ADCP-75-237 • Issue 1 • 8/2007 • Section 2: Installation Page 2-4 © 2007, ADC Telecommunications, Inc.
ADCP-75-237 • Issue 1 • 8/2007 • Section 3: Graphical User Interface SECTION 3: GRAPHICAL USER INTERFACE Content Page 1 INSTALL SOFTWARE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-1 2 OPERATING THE SOFTWARE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-5 2.1 Menu Information . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ADCP-75-237 • Issue 1 • 8/2007 • Section 3: Graphical User Interface Program automatically creates a default directory to install the program in. If you wish to change the installation directory, select “Change Directory” button to manually create a directory. Click icon on screen to begin installation. Page 3-2 © 2007, ADC Telecommunications, Inc.
ADCP-75-237 • Issue 1 • 8/2007 • Section 3: Graphical User Interface Choose a Program Group where program is to be installed. By default, the program creates a new program group named “Pcs_Repeater”. Click “Continue” button. Page 3-3 © 2007, ADC Telecommunications, Inc.
ADCP-75-237 • Issue 1 • 8/2007 • Section 3: Graphical User Interface If this software program is using an older window database there is a version conflict. Keep the original file by clicking “Yes” Successful installation completed. Click “OK” button. The window will automatically close. You do not need to re-start the computer to begin using the program. Page 3-4 © 2007, ADC Telecommunications, Inc.
ADCP-75-237 • Issue 1 • 8/2007 • Section 3: Graphical User Interface 2 OPERATING THE SOFTWARE After installing the program, run program by going to Windows “Start” menu -> “Program” -> Pcs_Repeater program group. Click “Pcs_Repeater” to start program. The following screen displays the start window of the program. 2.
ADCP-75-237 • Issue 1 • 8/2007 • Section 3: Graphical User Interface 2.2 Control Panel Information - Gain: Show current gain of the repeater system - Output Power: Show current output power - System Alarm: Show current alarm status • Isolation: When there is an error, Fwd.ShutDown, Rev.ShutDown, and Isolation signal buttons turn red. • PLL: When there is an error on PLL, the signal button turns red. • Fwd.
ADCP-75-237 • Issue 1 • 8/2007 • Section 3: Graphical User Interface - Equipment: • AGC ON/OFF: Select to apply this option to the system and press “Send” to apply the selection. • Sleep ON/OFF: Select to apply this option to the system and press “Send” to apply the selection. • SD (shut down) ON/OFF: Select to apply this option to the system and press “Send” to apply the selection. 850MHz Band Selection: • A”+A/A/x: 12.5MHz path band A”+A, A, or no selection (x) • B/B’/x: 12.
ADCP-75-237 • Issue 1 • 8/2007 • Section 3: Graphical User Interface 2.3 Status Bar - Status: Window bottom line Status shows connected/disconnected status and time being connected. Upper right side check box will also denote Communication status of connected activity. - Port: Window bottom line Port shows the connected port number - Properties: Window bottom line Properties shows the property information. Note: You must install a USB driver to use the USB port.
ADCP-75-237 • Issue 1 • 8/2007 • Section 3: Graphical User Interface - Port: Select serial port number from 1 to 16 - BaudRate: Select Baud rate “9600”bps - Data Type: DataBit: Select “8”bit, Parity: Select “None”, StopBit: Select “1” - Echo: Select “Off”, “LF” - Flow: Select “None” - H/W: Select both. All options may use default settings except for “Port”. You must select correct port # that the computer is connected to the equipment with.
ADCP-75-237 • Issue 1 • 8/2007 • Section 3: Graphical User Interface 4 US_PCS TEST SCREEN The Testing screen is opened by pressing the “F5” Function key. This window is used to test each attenuation, and test band selection or set PLL. 4.1 Fwd Base Volt Input 0dB signal to the repeater system, and click 0dB “Read” button. This will read the forward path voltage and show in the text box. Input +1dB signal to the repeater system, and click +1dB-”Read” button.
ADCP-75-237 • Issue 1 • 8/2007 • Section 3: Graphical User Interface 4.2 Rev Base Volt Repeat the FWD Base Volt set-up for the Rev Base Volt (Reverse Base Voltage). 4.3 Band Selection 850MHz 1900MHz A/B/C/x: 15MHz path band A, B, C, or no selection (x) D/E/F/x: 5MHz path band D, E, F, or no selection (x) Select to apply these options to the system and press “Apply” to apply the selections. 4.4 Attenuation Test: MGC / ALC Control Press up/down arrow key to adjust the Manual Gain Control in 0.
ADCP-75-237 • Issue 1 • 8/2007 • Section 3: Graphical User Interface Blank Page 3-12 © 2007, ADC Telecommunications, Inc.
ADCP-75-237 • Issue 1 • 8/2007 • Section 4: GENERAL INFORMATION SECTION 4: GENERAL INFORMATION Content Page 1 WARRANTY/SOFTWARE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-1 2 SOFTWARE SERVICE AGREEMENT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-1 3 REPAIR/EXCHANGE POLICY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ADCP-75-237 • Issue 1 • 8/2007 • Section 4: GENERAL INFORMATION 4 REPAIR CHARGES If the defect and the necessary repairs are covered by the warranty, and the applicable warranty period has not expired, the Buyer’s only payment obligation is to pay the shipping cost to return the defective Product. ADC will repair or replace the Product at no charge and pay the return shipping charges. Otherwise, ADC will charge a percentage of the current Customer Product price for the repair or NTF (No Trouble Found).
PHONE: U.S.A.