Use, Care, & Maintenance
Diagnostix
TM
Aneroids
Pocket, Palm, Clock Type
®
6. Measurement
Record the onset of Korotkoff sounds as the systolic pressure, and the disappearance
of these sounds as diastolic pressure. (Some healthcare professionals recommend
recording diastolic 1 and diastolic 2. Diastolic one occurs at phase 4).
NOTE: It is recommended that K4 be used in children aged 3 to 12, and K5 should
be used for pregnant female patients unless sounds are audible with the cuff deflated,
in which case K4 should be used. K5 should be used for all other adult patients.
After measurement is completed, open valve fully to release any remaining air in the
cuff. Remove cuff.
Care and Maintenance
STORAGE:
Pocket Gauge: After measurement, fully exhaust cuff then wrap cuff around gauge
and bulb and store in zippered carrying case.
Palm Gauge: After measurement, fully exhaust cuff and store in zippered carrying
case. If unit will not be used for an extended period of time, leave the trigger valve in
the full exhaust position.
Clock Gauge: After measurement, fully exhaust cuff then wrap cuff around bulb and
store in storage compartment.
NOTE: This product will maintain the safety and performance characteristics
specified at temperatures ranging from 50°F to 104°F (10°C to 40°C) at a relative
humidity level of 15% to 85%.
Manometer: Your ADC DIAGNOSTIX
TM
brand pocket aneroid gauge (#800 or #802),
palm aneroid (804) or clock aneroid (805) requires minimal care and maintenance.
The manometer may be cleaned with a soft cloth but
should not be dismantled under any circumstances.
Gauge accuracy can be checked visually; simply be
certain the needle rests within the printed oval when
the unit is fully deflated (Figure 3).
Should the indicator needle of the manometer rest
outside of this calibration mark, then the manometer
must be re-calibrated to within ±3 mmHg when compared to a reference device that
has been certified to national or international measurement standards. A manometer
whose indicator needle is resting outside of this mark, is NOT acceptable for use.
In the event that the gauge is ever in need of calibration, simply return to ADC.
Damaged or broken parts will be replaced as needed at a minimum charge. Refer to
the warranty for specific details of warranty coverage.
The manufacturer recommends a calibration check every 2 years.
Cuff Cleaning and Disinfecting
NOTE: Use one or more of the following methods and allow to air dry:
Wipe with mild detergent and water solution (1:9 solution). Rinse.
Wipe with Enzol per manufacturer’s instructions. Rinse.
Wipe with .5% bleach and water solution. Rinse
Wipe with 70% isopropyl alcohol.
Launder with mild detergent in warm water, normal wash cycle.
Remove bladder first. Cuff is compatible with 5 wash cycles.
Low Level Disinfection
Prepare Enzol enzymatic detergent according to the manufacturer’s instructions. Spray
detergent solution liberally onto cuff and use a sterile brush to agitate the detergent
solution over entire cuff surface for five minutes. Rinse continuously with distilled
water for five minutes. To disinfect, first follow the cleaning steps above, then spray cuff
with 10% bleach solution until saturated, agitate with a sterile brush over entire cuff
surface for five minutes. Rinse continuously with distilled water for five minutes. Wipe
off excess water with sterile cloth and allow cuff to air dry.
CAUTION: Do not iron cuff.
CAUTION: Do not heat or steam sterilize cuff.
Manometer Quality Control
A Serial number and Lot number are
automatically assigned to every aneroid
during manufacturing, ensuring every item
is "controlled".
The Serial Number can be located on the
faceplate of each aneroid (Figure 4).
The Lot number is located on the outside
label of the manometer packaging (Figure 5).
Standards
ANSI/AAMI/ISO 81060-1:2007 • ANSI/AAMI SP-10:2002
EN 1060-1:1995 • EN 1060-2:1995
Disposal
When your sphygmomanometer has reached its end of life, please be sure to dispose
of it in accordance with all regional and national environmental regulations. Devices
that have become contaminated should be disposed of in accordance with all local
ordinances and regulations.
Symbol Definitions
The following symbols are associated with your ADC
®
Diagnostix
TM
Aneroid
(Figure 4)
Serial Number
!
!
Warranty
American Diagnostic Corporation’s (ADC
®
) warranty service extends to the original
retail purchaser only and commences from the date of delivery. ADC warrants its
products against defects in materials and workmanship under normal use and service
as follows:
Your DIAGNOSTIX™ manometer is warranted for life.
The manometer is warranted to remain accurate to +/-3mmHg (or the
prevailing standard) over its full range when compared to a reference
standard for life.
Inflation system components (cuff, bladder, tubing, bulb, valves, connectors)
are warranted for three years.
What is Covered: Replacement of parts, and labor.
What is Not Covered: Transportation charges to and from ADC
®
. Damages
caused by abuse, misuse, accident, or negligence. Incidental, special, or
consequential damages. Some states do not allow the exclusion or limitation of
incidental, special, or consequential damages, so this limitation may not apply
to you.
To Obtain Warranty Service: Send item(s) postage paid to ADC
®
, Attn: Repair
Dept., 55 Commerce Dr., Hauppauge, NY 11788. Please include your name and
address, phone no., proof of purchase, and a brief note explaining the problem.
Implied Warranty: Any implied warranty shall be limited in duration to the terms
of this warranty and in no case beyond the original selling price (except where
prohibited by law). This warranty gives you specific legal rights and you may have
other rights which vary from state to state.
NOTE: Store gauge with
valve in full exhaust position.
(Figure 3)
***LATEX-FREE***
LOT 0 00000 000
DIAGNOSTIX
TM
Aneroid
SIZE: Adult
COLOR: Black
CONTENTS: 1 ea
Hauppauge, NY
0000-00
ADC
0000
!
REF
(Figure 5)
Lot Number
This manual is available online in a variety of
languages, follow the links for language options.
www.adctoday.com/care
To register your product visit us at
www.adctoday.com/register
FOR QUESTIONS, COMMENTS,
OR SUGGESTIONS CALL TOLL FREE:
1-800-ADC-2670
OR VISIT
www.adctoday.com/feedback
Symbol Definition
Important Warning/Caution
Latex-Free
Circumference Size
Symbol Definition
Conforms to EU Standards
Authorized European
Represenative’s Information
Manufacturers Information
0197

Summary of content (2 pages)