Installation manual

49
12. Steam damper system
is not functioning properly (FOR STEAM MODELS ONLY)...
a. Damper sticking closed.
b. Leak in pneumatic (air) system.
13. Failed electric oven element(s) (FOR ELECTRIC MODELS ONLY).
R. Condensation on main door glass...
1. Too long, undersized, or improperly installed ductwork.
2. Back draft damper is sticking in partially closed position.
S. Scraping noise at basket (tumbler) area...
1. Check for object caught in basket (tumbler)/wrapper area.
2. Basket (tumbler) is out of proper alignment...
a. Check both vertical and lateral alignment.
b. Check gap between front panel and basket (tumbler), setscrews may have come loose, and basket
(tumbler) walked forward or backwards.
3. Loose basket (tumbler) tie rod.
4. Failed basket (tumbler) support.
T. Excessive noise and/or vibration...
1. Dryer is not leveled properly.
2. Impellor (fan/blower) is out of balance...
a. Excessive lint build up on impellor (fan/blower).
b. Failed impellor (fan/blower).
3. Loose basket (tumbler) tie rod.
4. Basket (tumbler) is out of adjustment or adjustment bolts (hardware) are loose.
5. Failed basket (tumbler) support.
6. Loose motor mount.
7. Failed idler and/or basket (tumbler) bearings.
8. V-belt(s) either too tight or too loose.