Installation manual

52
E. Heat unit is not operating for only one (1) temperature selection...
1. Failed thermostat corresponding to selection made.
2. Failed heat selector switch.
F. Dryer operates but is taking too long to dry load...
1. Heating unit cycling on hi-limit thermostat (FOR ELECTRIC MODELS ONLY).
2. Steam damper binding in partially open position (FOR STEAM MODELS ONLY).
3. Lint and/or dust accumulation on steam coil fins (FOR STEAM MODELS ONLY).
4. Housekeeping...
a. Lint screen and lint compartment
are not being cleaned on a regular basis.
b. Lint accumulation in location exhaust system.
5. Insufficient make-up air.
6. Failed hi-limit thermostat (FOR ELECTRIC MODELS ONLY).
7. Extractors (washers)
is not performing properly.
8. Low and/or inconsistent gas pressure (FOR GAS MODELS ONLY).
9. Gas supply may have low heating value (FOR GAS MODELS ONLY).
10. Sail switch is fluttering (FOR GAS AND ELECTRIC MODELS ONLY)...
a. Restriction in location exhaust system.
11. Fault in electric oven element circuit (FOR ELECTRIC MODELS ONLY)...
a. Failed element(s).
b. Failed oven contactor (relay).
12. Exceptionally cold/humid or low barometric pressure atmosphere.
13. Blower (impellor/fan) motor rotation direction is incorrect.