Installation manual
59
SECTION X
MANUAL RESET HI-LIMIT INSTRUCTIONS
IMPOR TANT
MANUAL RESET HI-LIMIT INSTRUCTIONS
FOR NON-MICROPROCESSOR OR PHASE 5 WITHOUT HEAT FAULT
This dryer was manufactured with a burner manual reset hi-limit thermostat (gas models only) and a basket
(tumbler)/lint chamber manual reset hi-limit thermostat. If either burner manual reset hi-limit thermostat is open
prior to the start of the drying cycle, or during the cycle, the dryer
will not recognize the open state of the burner
hi-limit thermostat and will start or continue through the drying cycle with no heat. Manual reset hi-limit thermostat
must be reset manually.
This hi-temperature condition may be caused due to a restricted exhaust, poor airflow, or improper burner
oven operation.
IMPORTANT
This dryer is equipped with a burner hi-
limit and tumbler/lint chamber hi-limit
thermostat which must be reset manually.
WARNING: Discontinue power to dryer
before attempting to reset hi-limit.
ADC P/N: 114093