E. NO DISPLAY CONDITIONS
1. Check power supply. (dryer voltage 110v, 208v, 220v ...)
2. Check for voltage across (L1) and (L2) of motor relay.
(110v, 208v, 220v ...) For 3 phase machines, check
across (L1) and (L3). If no voltage is evident, problem
is bad wire(s) or termination from circuit breaker panel
to top of motor contactor.
3. Check the .5 amp fuse(s) in the control box. If dryer
is rated at 110v, 115v, or 120v there will only be one
fuse. Voltages of 208v, 220v will have two fuses. If
blown, replace with P/N: 136057
4. Check voltage across TB #8 and TB #6 (110v, 208v,
220v). If no voltage is evident, problem is bad wire or
termination from TB #8 and TB #6 to the L1 and L2
connection on the motor relay.
1Ø Motors