Operator`s manual

52
C. Blower motor (only) is not operating...
1. Failed impellor (fan/blower) motor contactor (relay).
2. Failed blower (impellor/fan) motor.
D. Both drive and blower motors is not operating (indicator light is on)...
1. Fault with L1 termination at reversing timer (for Reversing Models Only).
2. Failed drying timer.
E. Reversing drive motor operates in one direction only, stops, and restarts in same direction (for
Reversing Models ONLY)...
1. Failed reversing contactor (relay).
2. Failed reversing timer.
F. Heating unit is not operating (ALL temperature selections)...
GAS MODELS ONLY
1. Fault in sail switch circuit ...
a. Sail switch out of adjustment and/or failed.
b. Sail switch not closing or fluttering ...
1) Check blower (impellor/fan) motor and rotation direction.
2) Restriction in location exhaust system.
2. Tripped burner hi-limit circuit.
3. Tripped lint compartment manual reset (225º F [107º C]) safety thermostat circuit.
4. Failed heat selector switch.
ELECTRIC MODELS ONLY
1. Fault in sail switch circuit ...
a. Sail switch out of adjustment and/or failed.
b. Sail switch not closing or fluttering ...
1) Check blower (impellor/fan) motor and rotation direction.
2) Restriction in location exhaust system.
2. Failed oven hi-limit circuit.