Installation manual
6
SECTION II
SPECIFICATIONS
A. SPECIFICATIONS
* AD-30V reversing dryer available with 3-phase (3ø) 1/2 HP (0.373 kw) motors standard.
** Size of piping to dryer varies with installation conditions. Contact factory for assistance.
*** Contact factory for information not listed, 3-phase (3ø) figures shown are for 3-wire service.
**** Specify air-operated or electromechanical steam damper system. Air-operated steam damper system must be provided with
clean, dry and regulated 80 PSI ± 10 PSI (5.51 bars ± 0.68 bars) air supply.
NOTE: ADC reserves the right to make changes in specifications at any time without notice or
obligation.
Gas
ElectricSteam****
MAXIMUM CAPACITY (DRY WEIGHT) 30 lbs 13.6 kg
BASKET (TUMBLER) DIAMETER 32-3/4” 83.2 cm
BASKET (TUMBLER) DEPTH 25-5/8” 65.1 cm
BASKET (TUMBLER) MOTOR 1/2 HP* 0.373 kw
DOOR OPENING (DIAMETER) 21-1/2” 54.61 cm
BASKET (TUMBLER) VOLUME 12.5 cu. ft. 0.354 cu.m.
DRYERS PER 20’/40’ CONTAINER 12/26
DRYERS PER 45’/48’ TRUCK 30/32
VOLTAGE AVAILABLE 120-460v 1ø - 3ø 3, 4w 50/60 Hz
APPROX. WEIGHT (UNCRATED) 534 lbs 242 kg
APPROX. WEIGHT (CRATED) 571 lbs 259 kg
HEAT INPUT 100,000 btuh 25,200 kcal/hr
AIRFLOW 460 cfm 13 cmm
INLET PIPE CONNECTION 1/2” F.P.T.**
OVEN SIZE
KW
BTUH
(60 Hz)
KCAL/HR
(50 Hz)
20 68,250 17,200
24 81,900 20,640
APPLIED VOLTAGE/PHASE/APPROX. AMP DRAW***
KW
208/1Ø 240/1ø 208/3ø 240/3ø 380/3ø 416/3ø 460/3ø
60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz
20 102 --- 89 88 --- --- --- --- --- 33 --- --- --- ---
24 --- --- --- --- 70 --- 61 62 --- --- --- 36 32 ---
VOLTAGE AVAILABLE 120-460v 1ø - 3ø 3, 4w 50/60 Hz
APPROX. WEIGHT (UNCRATED) 593 lbs 269 kg
APPROX. WEIGHT (CRATED) 631 lbs 286 kg
AIRFLOW 460 cfm 13 cmm
COMPRESSED AIR VOLUME 0.5 cfh 0.014 cmh
AIR CONNECTION 1/8” F.P.T.
STEAM CONSUMPTION BOILER HP NORMAL LOAD
LOW 90.1 lbs/hr 40.9 kg/hr 2.6
HIGH 104 lbs/hr 47.2 kg/hr 3.0
OPERATING STEAM PRESSURE STEAM SUPPLY STEAM RETURN
LOW 15 PSI 1.03 bars 1” 1”
HIGH 125 PSI 8.6 bars 1” 1”
Shaded areas are stated in metric equivalents