Installation manual
52
C. Blower motor (only) is not operating...
1. Failed impellor (fan/blower) motor contactor (relay).
2. Failed blower (impellor/fan) motor.
D. Both drive motor and blower motor are not operating (indicator light is on)...
1. Fault with L1 termination at reversing timer (for reversing models only).
2. Failed drying timer.
E. Reversing drive motor operates in one (1) direction only, stops, and restarts in same direction
(for reversing models only)...
1. Failed reversing contactor (relay).
2. Failed reversing timer.
F. Heating unit is not operating (ALL temperature selections)...
GAS MODELS ONLY
1. Fault in sail switch circuit...
a. Sail switch is out of adjustment and/or failed.
b. Sail switch is not closing or fluttering...
1) Check blower (impellor/fan) motor and rotation direction.
2) Restriction in location exhaust system.
2. Fault in burner hi-limit circuit on tripped manual reset hi-limit.
3. Tripped lint compartment manual reset (225º F [107º C]) safety thermostat circuit.
4. Failed heat selector switch.
ELECTRIC MODELS ONLY
1. Fault in sail switch circuit...
a. Sail switch is out of adjustment and/or failed.
b. Sail switch is not closing or fluttering...
1) Check blower (impellor/fan) motor and rotation direction.
2) Restriction in location exhaust system.
2. Failed oven hi-limit circuit.