Clothes Dryer User Manual

8
The dryer must be connected to the type of gas (natural or liquid propane [L.P.]) indicated on the dryer
data label. If this information
does not agree with the type of gas available, contact the reseller who sold
the dryer or contact the ADC factory.
The gas input ratings shown on the dryer data label are for elevations up to 2,000 feet (609.6 meters),
unless elevation requirements of over 2,000 feet (609.6 meters) were specified at the time the dryer order
was placed with the factory. The adjustment for dryers in the field for elevations over 2,000 feet (609.6
meters) is made by changing the burner orifices. If this adjustment is necessary, contact the reseller who
sold the dryer or contact the ADC factory.
NOTE: Any burner changes must be made by a qualified technician.
C. OPERATIONAL SERVICE CHECK PROCEDURE
After performing any service or maintenance function, an operational check should be performed to insure that
ALL components are performing properly.
1. Make a complete operational check of
ALL the operating controls to insure that the timing is correct;
temperature selection switches are functioning properly.
2. Make a complete operational check of ALL safety related circuits, door switches, hi-limit thermostats, sail
switch, and cycling thermostats, etc.