Clothes Dryer User Manual

34
1.
Direct Spark Ignition (DSI) Troubleshooting Terms (Definitions)
a. LOCKOUT Mode - DSI module “GREEN” light emitting diode (L.E.D.) indicator light blinks
continuously. This indicates there is a system fault and most likely the fault is that the DSI module was
not able to ignite the gas.
b. FLAMEOUT - Burner flame shutdown by the DSI module due to lack of flame verification. This
condition occurs only after ignition has been evident, but, is lost. The system will attempt to relight the
burner after 30-seconds.
2. Troubleshooting/System Basic Diagnosis
a. Preliminary Steps - The following steps must be performed to minimize the time required to isolate
cause of fault.
1) DSI module L.E.D. indicator is off (no “GREEN” light).
a) Check for voltage (approximately 24 VAC) across the DSI module terminals “THS” and “GND”
(ground)...
If voltage (approximately 24 VAC) is evident, then, there is a malfunction within the DSI module
itself, and it must be replaced.
b) If there is no voltage, and the problem is not the DSI module or the ignition system, then the
problem is elsewhere in the dryer (i.e., dryers’ heat circuit [sail switch, hi-limit circuits, etc.]).
DSI IGNITOR GAP FEELER GAUGE (1/8”)
For checking the gap between ignitor assembly ground rod and spark electrode.
Available from ADC - Part No. 305410
MULTIMETER/VOLTMETER
For measuring voltage and/or amperage