E. Blower/Fan motor is not operating (does not start)...
1. Microprocessor controller (computer) motor indicator dot and relay output L.E.D. (light emitting
diode) indicator dots are on ...
a. Failed blower (impellor/fan) motor contactor (relay).
b. Failed arc suppressor (A.S.) board.
c. Failed blower (impellor/fan) motor.
2. Microprocessor controller (computer) "door" L.E.D. is on but motor output L.E.D. indicator is off...
a. Failed microprocessor controller (computer).
F. Blower/Fan motor (for Reversing Models ONLY) operates okay for a few minutes, then stops
and will not restart...
1. Motor is overheating and tripping out on internal overload protector ...
a. Motor air vents clogged with lint.
b. Low voltage to motor.
c. Failed motor.
d. Failed blower (impellor/fan)...out of balance.
G. Both drive motor and blower (impellor/fan) motor (for Reversing Models ONLY) are not
operating (does not start)...microprocessor (computer) motor indicator dots and relay output
L.E.D. (light emitting diode) indicators are on...
1. Failed arc suppressor (A.S.) board.
2. Failed contactors (both blower [impellor/fan] and drive).
3. Failed motors (both blower [impellor/fan] motor and drive motor).
H. Both drive motor and blower (impellor/fan) motor (for Reversing Models ONLY) are not
operating (does not start)...microprocessor (computer) L.E.D. motor indicator dots and the “door”
L.E.D. indicator are on but the relay output L.E.D. indicators are off (microprocessor
controller [computer] L.E.D. (light emitting diode) display does not read “door”)...
1. Failed microprocessor controller (computer).
I. Both drive motor and blower (impellor/fan) motor run a few minutes and stop...microprocessor
(computer) L.E.D. (light emitting diode) display continue to read time or percent of extraction
and ALL indicator dots are off...
1. Fault in main door switch circuit ...