W. At the completion of the "AUTO" drying/cooling cycle, the load is coming out over dried...
1. Percent of dryness (dryness level) of the cycle selected is too high.
2. Factor "A" and Factor "B" is not set correctly or Factor "B" has to be adjusted for adverse local
conditions.
X. At the completion of the "AUTO" drying/cooling cycle, the load is coming out still damp...
1. Percent of dryness (dryness level) of the cycle selected is too high.
2. Factor "A" and Factor "B" is not set correctly or Factor "B" has to be adjusted for adverse local
conditions.
Y. Main burners are burning with a yellow flame (for Gas Models ONLY)...
1. Poor air/gas mixture (too much gas or not enough air) at the burner ...
a. Not enough make-up air.
b. Restriction in the exhaust.
c. Gas pressure is too high.
d. Impellor (fan/blower) is rotating in the wrong direction only (for 3ΓΈ Models ONLY).
e. Burner orifice size (D.M.S. [drill material size]) too large for application (i.e., high elevation).
Z. Condensation on main door glass...
1. Too long, undersized, or improperly installed duct work.
2. Back draft damper is sticking in the partially closed position.
AA. Scraping noise at basket (tumbler) area...
1. Check for obstruction caught in basket (tumbler)/wrapper area.
2. Basket (tumbler) is out of proper alignment ...
a. Check both the vertical alignment and lateral alignment.
b. Check for gap between the front panel and basket (tumbler)...bearing set screws may have come
loose, and basket (tumbler) walked forward or backward.
3. Loose basket (tumbler) tie rod.
4. Failed basket (tumbler) support.