Instruction manual

Parameter
number
(DDE)
Parameter
name
Filter Value Description
2011-05-18 Page 4 of 5 FlowDDE database version V3.64
166 Controller features &H04 fixed monitor output signal0
166 Controller features &H04 monitor output changed at setpoint steps1
166 Controller features &H08 voltage drift compensation for valve output turned on0
166 Controller features &H08 voltage drift compensation for valve output turned off1
166 Controller features &H10 auto slope disabled0
166 Controller features &H10 auto slope enabled for pilot valves1
166 Controller features &H20 automatic correction for valve open turned on0
166 Controller features &H20 automatic correction for valve open turned off1
166 Controller features &H40 controller special mode (valve output steps) turned off0
166 Controller features &H40 controller special mode (valve output steps) turned on1
166 Controller features &H80 valve overshoot protection turned off0
166 Controller features &H80 valve overshoot protection turned on1
175 Identification number UFO?: Unidentified FLOW-BUS Object0
175 Identification number RS232/FLOW-BUS interface1
175 Identification number PC(ISA) interface2
175 Identification number ADDA4 (4 channels)3
175 Identification number R/C-module, 32 channels4
175 Identification number T/A-module5
175 Identification number ADDA1: 1 channel ADDA converter module6
175 Identification number DMFC: digital mass flow controller7
175 Identification number DMFM: digital mass flow meter8
175 Identification number DEPC: digital electronic pressure controller9
175 Identification number DEPM: digital electronic pressure meter10
175 Identification number ACT: single actuator11
175 Identification number DLFC: digital liquid flow controller12
175 Identification number DLFM: digital liquid flow meter13
175 Identification number DSCM-A: digital single channel module for analog instruments14
175 Identification number DSCM-D: digital single channel module for digital instr.15
175 Identification number FRM: FLOW-BUS rotor meter (calibration-instrument)16
175 Identification number FTM: FLOW-BUS turbine meter (calibration-instrument)17
175 Identification number FPP: FLOW-BUS piston prover/tube (calibration-instrument)18
175 Identification number F/A-module: special version of T/A-module19
175 Identification number DSCM-E: evaporator controller module (single channel)20
175 Identification number DSCM-C: digital single channel module for calibrators21
175 Identification number DDCM-A: digital dual channel module for analog instruments22
175 Identification number DMCM-D: digital multi channel module for digital instruments23
175 Identification number Profibus-DP/FLOW-BUS interface module24
175 Identification number FLOW-BUS Coriolis Meter25
175 Identification number FBI: FLOW-BUS Balance Interface26
175 Identification number CORIFC: CoriFlow Controller27
175 Identification number CORIFM: CoriFlow Meter28
175 Identification number FICC: FLOW-BUS Interface Climate Control29
175 Identification number IFI: Instrument FLOW-BUS Interface30
175 Identification number KFI: Keithley FLOW-BUS Interface31
175 Identification number FSI: FLOW-BUS Switch Interface32
175 Identification number MSCI: Multi-Sensor/Confroller Interface33
175 Identification number APP-D: Active Piston Prover34
175 Identification number LFI: Leaktester FLOW-BUS Interface35
185 Device function Unknown0
185 Device function Interface1
185 Device function ADDA2
185 Device function Operator3
185 Device function Supervisor (totalizer/alarm)4
185 Device function Controller5
185 Device function Meter6
185 Device function Special7
185 Device function (Protocol) converter8
197 Calibrations options &H01 Automatic capacity setting for optimal resolution0
197 Calibrations options &H01 Manual capacity setting for optimal resolution1
197 Calibrations options &H02 Barometer value input via parameter 107: BaroPress0
197 Calibrations options &H02 Barometer is master; input automatically from master1
200 Interface configuration Configuration A: 14 ch. Standard parms. with network scan0
200 Interface configuration Configuration B: 14 ch. Standard parms with fixed chan list1
200 Interface configuration Configuration C: 7 ch. Extended parms with fixed chan list2
200 Interface configuration Configuration D: 11 ch. Extended parms with network scan3
208 Manufacturer status regi &H800000 No diagnostics available in manufacturer status register0
208 Manufacturer status regi &H800000 Diagnostics available in manufacturer status register1
209 Manufacturer warning re &H800000 No diagnostics available in manufacturer warning register0
209 Manufacturer warning re &H800000 Diagnostics available in manufacturer warning register1
210 Manufacturer error regis &H800000 No diagnostics available in manufacturer error register0
210 Manufacturer error regis &H800000 Diagnostics available in manufacturer error register1
212 Diagnostic mode Debug mode off0
212 Diagnostic mode Debug mode on1
213 Manufacturer status ena set status bit (range 0…127)0
213 Manufacturer status ena set status bit (range 0…127)127
213 Manufacturer status ena clear all status bits254
213 Manufacturer status ena set all status bits255
232 Valve mode voltage drive mode0
232 Valve mode current drive mode1
238 Fluidset properties &H01 Fluidset is disabled0
238 Fluidset properties &H01 Fluidset is enabled1
238 Fluidset properties &H02 Fluidset is not set by Bronkhorst High-Tech0
238 Fluidset properties &H02 Fluidset is set by Bronkhorst High-Tech2
238 Fluidset properties &H04 Fluidset is not calibrated on actual gas0