User manual

Configuring and Monitoring Through the LCD
4-6 Campus-RS Fractional Interface Card User Manual
There are three steps to setting the data rate:
setting the HDSL Standard Mode Rate, as described in “Selecting a
Standard HDSL Rate” on page 3-3
setting the rate multiplier
choosing from the list of available data rates, determined by the rate
multiplier and the HDSL Rate
Set the Rate Multiplier
The Rate Multiplier determines the size of each data packet that is transmitted
or received through the data port. It can be set to one of the following:
64 KBPS
56 KBPS
To set the Rate Multiplier:
1 Press Escape until CAMPUS RS I/F: FRAC displays.
2 Press Next until DATA PORT CONFIG & STATUS displays, then press
Enter. RATE MULTIPLIER displays.
3 Press Enter. The LCD displays the current rate multiplier.
4 Press Next until the desired option displays, then press Enter.
RATE MULTIPLIER along with the new setting display.
If you change the Rate Multiplier, the Data Port Rate changes
automatically to reflect the new multiplier.