User manual

Configuring and Monitoring Through the LCD
Campus-RS Fractional Interface Card User Manual 4-7
Choose the Data Rate
To set the Data Rate:
1 Press Escape until CAMPUS RS I/F: FRAC displays.
2 Press Next until DATA PORT CONFIG & STATUS displays, then press
Enter. RATE MULTIPLIER displays.
3 Press Next until DATA PORT RATE displays, then press Enter.
4 Press Next until the desired option displays, then press Enter.
DATA PORT RATE along with the new setting display.
Extended Mode Data Rates
In Extended HDSL Mode, the data port of the Fractional Interface Card is
determined by the HDSL rate. That is, the data port rate can be changed only
by changing the HDSL Rate. However, for each HDSL rate, the data port
Rate Multiplier can be set to accommodate n x 56 kbps or n x 64 kbps
operation, as shown in the following table.